72 / 101 page ![]() Dual RPM-Based PWM Fan Controller with Hardware Thermal Shutdown Datasheet Revision 1.74 (05-08-08) 72 SMSC EMC2104 DATASHEET 6.27 Fan Minimum Drive Registers The Fan Minimum Drive Register stores the minimum drive setting for each RPM based Fan Speed Control Algorithm. The RPM based Fan Speed Control Algorithm will not drive the fan at a level lower than the minimum drive unless the target Fan Speed is set at FFh (see Section 6.30) During normal operation, if the fan stops for any reason (including low drive), the RPM based Fan Speed Control Algorithm will attempt to restart the fan. Setting the Fan Minimum Drive Registers to a setting that will maintain fan operation is a useful way to avoid potential fan oscillations as the control circuitry attempts to drive it at a level that cannot support fan operation. The Fan Minimum Drive Register is software locked. 6.28 Valid TACH Count Registers The Valid TACH Count Register stores the maximum TACH Reading Register value to indicate that the each fan is spinning properly. The value is referenced at the end of the Spin Up Routine to determine if the fan has started operating and decide if the device needs to retry. See Equation [3] for translating the count to an RPM. This register is only used when the FSC is active. If the TACH Reading Register value exceeds the Valid TACH Count Register (indicating that the Fan RPM is below the threshold set by this count), then a stalled fan is detected. In this condition, the algorithm will automatically begin its Spin Up Routine. If a TACH Target setting is set above the Valid TACH Count setting, then that setting will be ignored and the algorithm will use the current fan drive setting. The Valid TACH Count Register is software locked. Table 6.42 Minimum Fan Drive Registers ADDR R/W REGISTER B7B6B5 B4 B3 B2B1B0 DEFAULT 48h R/W Fan 1 Minimum Drive 128 643216 8 4 2 1 66h (40%) 88h R/W Fan 2 Minimum Drive 128 643216 8 4 2 1 66h (40%) Table 6.43 Valid TACH Count Registers ADDR R/W REGISTER B7B6 B5 B4B3B2 B1B0 DEFAULT 49h R/W Valid TACH Count 1 4096 2048 1024 512 256 128 64 32 F5h 89h R/W Valid TACH Count 2 4096 2048 1024 512 256 128 64 32 F5h |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |