29 / 68 page ![]() L99MM70XP Protection and diagnosis Doc ID 022637 Rev 2 29/68 If the output current exceeds the current shutdown threshold the output transistor is turned off and the corresponding diagnosis bit of the output is latched. The status can be read and cleared from SPI. If the overcurrent recovery mode is set for this output, the output is switched on again in order to provide a soft start function (see Section 3.10.5: Programmable soft start function) and the status bit is cleared automatically. Otherwise the output stays off until the status bit is cleared. The outputs are automatically switched off in case of passive mode, VS undervoltage, VS overvoltage, thermal shutdown (TSD1 and TSD2) or stuck at 1/0 condition at DI. 4.5 High-side driver outputs The device provides a total of 4 high-side outputs OUT6,7,8,9 to drive LED or defroster. The high-side outputs are protected against ● Overvoltage and undervoltage (can be masked by SPI) ● Overload (short circuit) ● Overtemperature with pre warning If the output current exceeds the current shutdown threshold the output transistor is turned off and the corresponding diagnosis bit of the output is latched. The status can be read and cleared from SPI. If the overcurrent recovery mode is set for this output, the output is switched on again in order to provide a soft start function (see Section 3.10.5: Programmable soft start function) and the status bit is cleared automatically. Otherwise the output stays off until the status bit is cleared. The outputs are automatically switched off in case of passive mode, VS undervoltage, VS overvoltage, thermal shutdown (TSD1 and TSD2) or stuck at 1/0 condition at DI. Note: Loss of ground or ground shift with externally grounded loads: ESD structures are configured for nominal currents only. If external loads are connected to different grounds, the current load must be limited to this nominal current. |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |