Back Button SI4464 Datasheet HTML 5Page - Silicon Laboratories SI4464 Datasheet HTML 6Page - Silicon Laboratories SI4464 Datasheet HTML 7Page - Silicon Laboratories SI4464 Datasheet HTML 8Page - Silicon Laboratories SI4464 Datasheet HTML 9Page - Silicon Laboratories SI4464 Datasheet HTML 10Page - Silicon Laboratories SI4464 Datasheet HTML 11Page - Silicon Laboratories SI4464 Datasheet HTML 12Page - Silicon Laboratories SI4464 Datasheet HTML 13Page - Silicon Laboratories Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 56 page
background image
Si4464/63/61/60
Rev 1.2
9
Table 4. Transmitter AC Electrical Characteristics1
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
TX Frequency
Range (Si4463/61/60)
FTX
850
1050
MHz
420
525
MHz
284
350
MHz
142
175
MHz
TX Frequency
Range (Si4464)
FTX
705
960
MHz
353
639
MHz
177
319
MHz
119
159
MHz
(G)FSK Data Rate3,4
DRFSK
0.1
500
kbps
4(G)FSK Data Rate3,4
DR4FSK
0.2
1000
kbps
OOK Data Rate3,4
DROOK
0.1
120
kbps
Modulation Deviation
Range3
f960
850–1050 MHz
—1.5
MHz
f525
420–525 MHz
—750
kHz
f350
283–350 MHz
—500
kHz
f175
142–175 MHz
—250
kHz
Modulation Deviation
Range (Si4464)3
f960
705–960 MHz
—1.5
MHz
f639
470–639 MHz
—1
MHz
f479
353–479 MHz
—750
kHz
f319
235–319 MHz
—500
kHz
f239
177–239 MHz
—375
kHz
f159
119–159 MHz
—250
kHz
Notes:
1.
All specification guaranteed by production test unless otherwise noted. Production test conditions and max limits are
listed in the "Production Test Conditions" section in "1.1. Definition of Test Conditions" on page 14.
2.
For applications that use the major bands covered by Si4463/61/60, customers should use those parts instead of
Si4464.
3.
Guaranteed by qualification. Qualification test conditions are listed in the "Qualification Test Conditions" section in "1.1.
Definition of Test Conditions" on page 14.
4.
The maximum data rate is dependant on the XTAL frequency and is calculated as per the formula:
Maximum Symbol Rate = Fxtal/60, where Fxtal is the XTAL frequency (typically 30 MHz).
5.
Default API setting for modulation deviation resolution is double the typical value specified.
6.
Output power is dependent on matching components and board layout.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56


Fiches technique Télécharger

Go To PDF Page


Lien URL



ALLDATASHEET vous a-t-il été utile ?  [ DONATE ] 

À propos de Alldatasheet   |   Publicité   |   Contactez-nous   |   Politique de confidentialité   |   Lien vers la fiche technique    |   Echange de liens   |   Fabricants
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com