15 / 88 page ![]() DS12511 Rev 5 15/88 L99UDL01 Device description 87 The 3V3 supply has a low voltage warning function with hysteresis. When the 3V3 regulator drops below 3V3UV threshold for t3V3UV, timed actuation is halted, the outputs (internal half bridges and drivers for external MOSFET) are disabled, and the V3V3UV bit is set in the SPI diagnostic register 13h. If, for any reason the 3V3 supply falls below V3V3RST_F the Logic State machine and all of the registers are RESET to their default state and held there. Upon rising out of V3V3RST_R RESET will be disabled and the L99UDL01 will enter Standby mode. The C3V3 pin is intended only for supply to the IC. It is not recommended that the C3V3 pin is used to power any other circuitry. 2.3 Charge pump The charge pump uses two external flying capacitors, which are switched with fCP. The output of the charge pump has a current limitation. In standby mode or after a global thermal shutdown has been triggered the charge pump is disabled. Figure 3. Charge pump low filtering and start-up At coming out of standby the outputs are enabled tSET_CP seconds after the charge pump is re-enabled as long as the VCPLOW threshold is achieved. The CPLOW bit will remain set, indicating that the charge pump was low since the last reading of the register. At any time the charge pump output voltage drops below VCPLOW the CPLOW bit is set and the internal half bridges and the external H-Bridge MOSFET gate drivers are pulled low. After a CPLOW event the outputs are re-enabled tCP seconds after the charge pump voltage rises above VCPLOW. Actuation can be restarted via SPI frame or EN_OUT rising edge according to configuration registers. In this case the outputs that are actuated by the output override (OUTx_on) bits will automatically turn back on when the charge pump is above CPLOW. An over voltage or under voltage fault (VSovsd, VDDuv, V3V3uv) will disable the charge pump only while that condition exists. The charge pump will automatically restart once the over voltage or under voltage fault is no longer present. In the case of a global TSD event all of the TSD flags must be cleared or the ACT_OFF control bit must be reset to re-enable the Charge pump. Any time the charge pump is enabled, re-enabled or restarted the drivers will not be available until after tset_CP and the charge pump voltage exceeds the VCPLOW threshold (see Figure 3). Charge Pump VCP_Low Filter Time (tcp) Start-up Blanking time (tset_CP) CLK Power Stage Disable |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |