37 / 147 page ![]() • Comparator for the high-side (HS) and low-side (LS) drain-source voltage monitoring • The checked node can go up or down and it is not bounded to the pull-up value of the off state Ishx_PU and Ishx_PD can be activated for each half-bridge only if the bridge driver is in active mode as set by the control bits OUTEx, x = 1…8. Also Ishx_PU and Ishx_PD can be activated only when the off-state diagnostic is enabled by the microcontroller. The Vds comparators change their state after a filter time called tDIAG. The faults in the DSRx are not latched and the configurations placed in the registers are bypassed during diag off. The Ishx_PU ,and Ishx_PD values can be selected by using the DIAGOFF_CURR_SEL register. The L99MH98 determines the voltage at SHx, using the drain-source overvoltage comparators of the high-side or low-side MOSFETs. The microcontroller can read the status bit VDS_HSx_DIAG, x = 1...8, or the status bit VDS_LSx_DIAG, x = 1...8 to determine if VSHx is high or low. The diagnostic process is controlled by the microcontroller, whose task is: • To activate and deactivate Ishx_PU and Ishx_PD, controlled by the HB_IDIAGx registers • To read and interpret the status bits VDS_LSx_DIAG and VDS_HSx_DIAG The following conditions are equivalent in the rest of this document: • VDS_HSx_DIAG = VDS_LSx_DIAG = 0: SHx is low • VDS_HSx_DIAG = VDS_LSx_DIAG = 1: SHx is high 5.4.2 Example with a DC motor controlled by two half-bridges This section gives an example of an off-state diagnostic with one DC motor controlled by the half-bridges 1 and 2. The voltages at SH1/SH2 (noted VSH1/VSH2) are analyzed in the following test configurations: • Configuration 1 Ishx_PU HB1 OFF, Ishx_PU HB2 OFF, Ishx_PD HB1 ON, Ishx_PD HB2 ON • Configuration 2 Ishx_PU HB1 ON, Ishx_PU HB2 OFF, Ishx_PD HB1 OFF, Ishx_PD HB2 ON • Configuration 3 Ishx_PU HB1 OFF, Ishx_PU HB2 ON, Ishx_PD HB1 ON, Ishx_PD HB2 OFF Figure 20. Simplified block diagram with one DC motor controlled by two half-bridges VDS_HSx + - VDS_HSx_DIAG VDS_LSx + - VDS_LSx_DIAG VDH GND VSHx_OL IPD IPU IPD IPU SH1 SH2 GND GND VSHx_OL M VDS_HSx + - VDS_HSx_DIAG VDS_LSx + - VDS_LSx_DIAG GH1 GL1 GH2 GL2 VODLS = 1.8 V VODLS = 1.8 V VODHS = 1.8 V VODHS = 1.8 V + - + - + - + - 5.4.3 Normal load conditions Configuration 1 • Ishx_PU HB1 OFF, Ishx_PD HB1 ON • Ishx_PU HB2 OFF, Ishx_PD HB2 ON In normal conditions, the motor is connected between SH1 and SH2 without any short circuit. If Ishx_PU of HB1 and HB2 are off, the SH1 and SH2 are pulled down by Ishx_PD of HB1 and HB2 (see the Figure 21), so VDS_LS1 = VDS_LS2 = LOW and VDS_HS1 = VDS_HS2 = HIGH. L99MH98 Protections and diagnostics DS14611 - Rev 3 page 37/147 |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |