L99MH98 Fiches technique(PDF) 35 Page - STMicroelectronics

No de pièce L99MH98
Description  Automotive octal half-bridge pre-driver
PDF  147 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricant  STMICROELECTRONICS [STMicroelectronics]
Site Internet  http://www.st.com
Logo STMICROELECTRONICS - STMicroelectronics

L99MH98 Fiches technique(HTML) 35 Page - STMicroelectronics

Back Button L99MH98 Datasheet HTML 31Page - STMicroelectronics L99MH98 Datasheet HTML 32Page - STMicroelectronics L99MH98 Datasheet HTML 33Page - STMicroelectronics L99MH98 Datasheet HTML 34Page - STMicroelectronics L99MH98 Datasheet HTML 35Page - STMicroelectronics L99MH98 Datasheet HTML 36Page - STMicroelectronics L99MH98 Datasheet HTML 37Page - STMicroelectronics L99MH98 Datasheet HTML 38Page - STMicroelectronics L99MH98 Datasheet HTML 39Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 35 / 147 page
background image
5
Protections and diagnostics
5.1
Reverse polarity protection
The output of the charge pump (CPOUT pin) can be used to supply an external n-channel MOSFET, building an
active reverse polarity protection (refer to the Figure 19).
5.2
Programmable cross current protection time (DT)
In any input mode (octal half-bridge mode or full-bridge mode), the device adds the configured dead-time between
the turn-off of a MOSFET and the turn-on of the complementary one (that is, the other MOSFET of the same leg)
to avoid cross-conduction in any of the half-bridges. Two different methods have been implemented to choose the
starting point of the cross-current protection time according to the DTP_REF bit. If the DTP_REF = 0, the cross-
current protection time is calculated starting from the command to switch off a MOSFET and switch on the
complementary. If the DTP_REF = 1, the cross current protection time is calculated starting from the instant in
which the Vgs of the MOSFET being switched off has reached the value set in the VSTEP1x.In octal half-bridge
mode each half-bridge dead-time tDTxxx is independently configurable by control bits DTx[2:0], x = 1...8.
5.3
Short circuit detection/drain source monitoring (DSHS/DSLS)
The voltage-drop over each MOSFET is sensed and compared to a programmable threshold to detect an
overcurrent condition. This monitoring is activated only on the external MOSFETs of the half bridges driven to be
ON. In the L99MH98 each half-bridge has its own programmable threshold (VDS_CONFx[3:0], x = 1...8), blanking
time (VDS_BLANKx[3:0], x = 1...8) and filtering time (VDS_FILTx[2:0], x = 1...8).
As soon as the gate driver starts to turn ON a MOSFET, the corresponding drain source monitoring comparator
output is masked for the programmed blanking time to give time to the MOSFET to turn on. After the blanking
time is expired, a filtering time is applied to filter noise. Both values must be chosen depending on the application.
If the voltage-drop over the driven MOSFET exceeds the programmed threshold voltage VSCdx
(VDS_CONFx[3:0], x = 1...8) for a time longer than the programmed filtering time (and the programmed blanking
time, where applicable), either the gate drivers belonging to the faulty leg are forced to switch off actively the half-
bridge MOSFETs with the maximum available current, regardless of the programmed gate discharge current bits.
In any case the drain source monitoring flag VDSHSx, x = 1…8, or VDSLSx, x = 1...8, of the MOSFET detecting
the fault is set. The drain source monitoring flags must be cleared through SPI to reactivate the affected half-
bridge/full-bridge gate drivers that are forced in disabled mode. The drain source monitoring flag VDSHSx/
VDSLSx can be cleared by an SPI “read and clear” command only if the fault condition is no longer present.
If the voltage-drop over the driven MOSFET still exceeds the programmed threshold voltage VSCdx
(VDS_CONFx[3:0], x = 1...8) for a time longer than the programmed filtering time (and the programmed blanking
time, where applicable) after the SPI “read and clear” command, the drain source monitoring flag VDSHSx, x =
1...8, or VDSLSx, x = 1...8 will be set again. It is up to the microcontroller to decide how many attempts to make
before finally turning off the half-bridges where the over current is present.
L99MH98
Protections and diagnostics
DS14611 - Rev 3
page 35/147



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Fiches technique Télécharger

Go To PDF Page


Lien URL



ALLDATASHEET vous a-t-il été utile ?  [ DONATE ] 

À propos de Alldatasheet   |   Publicité   |   Contactez-nous   |   Politique de confidentialité   |   Lien vers la fiche technique    |   Echange de liens   |   Fabricants
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com