16 / 39 page ![]() 16 ACE9030 Fig. 13 Typical Lock Detect Waveforms Pulses can occur on the LOCK signal at a rate up to the higher of the Main and Auxiliary comparison frequencies, and typically either 12·5 kHz for ETACS (50 kHz if Fractional-N is used) or 30 kHz for AMPS so some extra filtering is needed to get a clean lock indicator. LOCK is filtered by first sampling at 504 kHz (the bus clock CL divided by two) and then counting the number of HIGH samples in a pre-determined period. There are two selections available for this counting period, approximately 160 µs (2 periods of 12·5 kHz or 8 of 50 kHz) or approximately 167 µs (5 periods of 30 kHz) which are set by a second counter, also running at 504 kHz and with a fixed modulus of 80 or 84. LOCK is stable for each comparison period so the counts for each comparison frequency are always in blocks of 40 for 12·5 kHz, 10 for 50 kHz or 16 for 30 kHz. The value in the LOCK sample counter is compared with a threshold previously set by another bus command, to determine if the loops are locked, the result is then output as the last bit in the pre-amble word in the response to a Normal command, before the ADC levels are given, as described in the section Polling A to D converter. The filter period is selected by the following Set-up command where DATA1 bit D 5 sets the period to one of the two values to suit whichever cellular system is to be used: DATA1 DATA2 DATA3 xx D 5 xxxxx 10xxxxxx xx1xxx00 DATA1:5 = 0 sets 160 µs for ETACS (Window count = 80) and DATA1:5 = 1 sets 167 µs for AMPS (Window count = 84). The threshold is set by a Normal command: DATA1 bits D 7 to D1 form a 7 bit binary number in the range Polling A To D Converter A five channel polling Analog to Digital Converter is used to monitor various analog levels, such as Received Signal Strength, Transmitter Power, Temperature and Battery Volt- age. The 8 bit ADC has a nominal range of 0·15 V to 3·45 V for codes 00 to FF and is connected to each input channel, ADC1 to ADC5, in turn by the scanning logic. The results are put into individual registers for reading by the microcontroller. The successive approximation technique is used, with the bus clock CL controlling both the timing of the conversion and also the polling around the inputs. The voltage reference for the ADC is shared with the three DAC’s and is derived from the bandgap voltage through a trimming multiplier which can be monitored on DOUT8 and is described in the section Band- Gap Reference. Some channels are scanned more frequently than others, with the pattern: 5, 1, 5, 2, 5, 1, 5, 3, 5, 1, 5, 4, which repeats continuously. With clock CL at its normal 1008 kHz frequency, the scanning rates are 12·6 kHz for ADC5, 6·3 kHz for ADC1 and 2·1 kHz for ADC2, 3 and 4. Channels 2 and 3 each have two options, 2A, 2B and 3A, 3B as pins to connect to alternative points to monitor. The selection is by a Set-up command: DATA1 DATA2 DATA3 xxxxxxxx 10xxx D 2 D1 x xxxxxx00 where DATA2 bit D 2 selects ADC3B when HIGH or ADC3A when LOW for measurement by channel 3, and DATA2 bit D 1 selects ADC2B when HIGH or ADC2A when LOW for meas- urement by channel 2. 0 to 127, which is the threshold value to be loaded. The window period of 80 or 84 clock cycles sets the maximum count value that can be found; the effect of unlock is to reduce the actual count by at least one comparison period’s worth of samples 40, 10, or 16 so a suitable threshold can easily be chosen. Assuming that the maximum sensitivity is required the thresh- old should be set at just above the maximum count (80 or 84) minus the effect of one unlock count (40, 10, or 16), to give suggested thresholds of at least 42 (for 12·5 kHz) or 72 (for 50 kHz) or 70 (for 30 kHz). In each case any convenient number between these suggestions and the maximum count may be used as the selection is not critical. DATA1 DATA2 DATA3 D 7 D6 D5 D4 D3 D2 D1 x 01x1xxxx xxxxxxxx INDICATES ACTIVE EDGE IN THE PHASE COMPARATOR LOCK ADEQUATE LOCK UNLOCK + 2 X XO REF.CLOCK (XO) COMP. FREQ. (MAIN) TIME WINDOW (MAIN) PROG. DIVIDER (MAIN) MAIN LOCK AUX.LOCK, DERIVED SIMILARLY LOCK |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |