| Moteur de recherche de fiches techniques de composants électroniques |
|
AN4124 Fiches technique(PDF) 20 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN4124 Fiches technique(HTML) 20 Page - STMicroelectronics |
|
20 / 32 page ![]() Redundancy and functions AN4124 20/32 Doc ID 023294 Rev 2 For some faults (Critical Faults): ● RGM and FCCU react to the fault independently. ● RGM resets the device (LR). – FCCU is not reset by RGM reset. ● FCCU takes some action depending on the configuration. – FCCU signals the fault externally. – after the reset the device enters SAFE mode. –NMI Figure 5. RGM/FCCU – dual path faults (critical faults) For some faults (Non-critical Faults): ● RGM and FCCU react to the fault independently/ ● RGM reaction is configurable. –IRQ ● FCCU takes some action depending on the configuration. – FCCU waits for the NCF timeout. – FCCU signals the fault externally. – device enters SAFE mode –NMI Figure 6. RGM/FCCU – dual path faults (Non-critical Faults) |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|