| Moteur de recherche de fiches techniques de composants électroniques |
|
ST20C2 Fiches technique(PDF) 197 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST20C2 Fiches technique(HTML) 197 Page - STMicroelectronics |
|
197 / 212 page ![]() wait 197/212 ® wait wait Code: 60 F5 Description: Wait (or P) on the semaphore pointed to by Areg. If the semaphore count is greater than zero then the count is decremented and the process continues; otherwise the current process is descheduled and added to the back of the semaphore list. Definition: if (word[Areg @ s.Count] = 0) { Put process on back of semaphore list Start next process } else word ′[Areg @ s.Count] ← word[Areg @ s.Count] − 1 Areg ′← undefined Breg ′← undefined Creg ′← undefined Error signals: none Comments: Secondary instruction. Instruction is a descheduling point. See also: signal |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|