12 / 27 page ![]() Internal RC oscillator calibration AN4067 12/27 DocID022913 Rev 2 Figure 7. Hardware connection using LSE as the reference frequency 1. TI1_RPM: TIM14 input 1 remapping 2. TI1_RPM: Timer input 1 3. IC1PS: Input capture 1 prescaled Note: It is also possible to use MCO for this purpose. 3.2.2 Case where another source is used as the reference frequency to measure HSI Any signal with an accurate frequency can be used for the internal oscillator calibration, and the external signal is one of the possibilities. As shown in Figure 8 below, the reference signal should be connected to Timer 14 channel 1. Figure 8. Hardware connection using external reference frequency 1. TI1_RPM: TIM14 input 1 remapping 2. TI1: Timer input 1 3. IC1PS: Input capture 1 prescaled |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|