28 / 37 page ![]() Class B solution structure AN3307 28/37 Doc ID 18186 Rev 4 interval (more than +/- 25% of its nominal value), the CPU clock source is immediately switched back to HSI, and HSE fail status is returned. Otherwise the test returns the OK status. In either case, the CPU clock is switched back to the default HSI source after the test is finished. Figure 13. Clock frequency measurement principle MS18599V1 Accepted range SysTick Timer (on HSI / HSE) RTC Timer (always on LSE) F ~ Ref F << Ref F >> Ref Run time measurement Initial reference measurement Reference level Zero level Auto reload level Zero level |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|