| Moteur de recherche de fiches techniques de composants électroniques |
|
NRF7002-CEAA-R7 Fiches technique(PDF) 7 Page - Nordic Semiconductor |
|
|
|||||||||||||||||||||||||||||
NRF7002-CEAA-R7 Fiches technique(HTML) 7 Page - Nordic Semiconductor |
|
7 / 69 page ![]() About this document 2.3.1 Fields and values The Id (Field Id) row specifies the bits that belong to the different fields in the register. If a field has enumerated values, then every value will be identified with a unique value id in the Value Id column. A blank space means that the field is reserved and read as undefined, and it also must be written as 0 to secure forward compatibility. If a register is divided into more than one field, a unique field name is specified for each field in the Field column. The Value Id may be omitted in the single-bit bit fields when values can be substituted with a Boolean type enumerator range, e.g. true/false, disable(d)/enable(d), on/ off, and so on. Values are usually provided as decimal or hexadecimal. Hexadecimal values have a 0x prefix, decimal values have no prefix. The Value column can be populated in the following ways: • Individual enumerated values, for example 1, 3, 9. • Range of values, e.g. [0..4], indicating all values from and including 0 and 4. • Implicit values. If no values are indicated in the Value column, all bit combinations are supported, or alternatively the field's translation and limitations are described in the text instead. If two or more fields are closely related, the Value Id, Value, and Description may be omitted for all but the first field. Subsequent fields will indicate inheritance with '..'. A feature marked Deprecated should not be used for new designs. 2.3.2 Permissions Different fields in a register might have different access permissions enforced by hardware. The access permission for each register field is documented in the Access column in the following ways: Access Description Hardware behavior RO Read-only Field can only be read. A write will be ignored. WO Write-only Field can only be written. A read will return an undefined value. RW Read-write Field can be read and written multiple times. W1 Write-once Field can only be written once per reset. Any subsequent write will be ignored. A read will return an undefined value. RW1 Read-write-once Field can be read multiple times, but only written once per reset. Any subsequent write will be ignored. W1C Write 1 to clear Field can be read multiple times. Bits set to 1 clear (set to zero) the corresponding bit in the register. Bits set to 0 are ignored. W1S Write 1 to set Field can be read multiple times. Bits set to 0 clear (set to zero) the corresponding bit in the register. Bits set to 1 are ignored. Table 2: Register field permission schemes 4486_184 v1.2 7 |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |