| Moteur de recherche de fiches techniques de composants électroniques |
|
NZMN2-AX160 Fiches technique(PDF) 2 Page - Eaton All Rights Reserved. |
|
|
|||||||||||||||||||||||||||||
NZMN2-AX160 Fiches technique(HTML) 2 Page - Eaton All Rights Reserved. |
|
2 / 5 page ![]() - NZM4, N4: vertical with remote operator: - NZM2, N(S)2, NZM3, N(S)3, NZM4, N(S)4: vertical and 90° in all directions Direction of incoming supply as required Degree of protection Device In the operating controls area: IP20 (basic degree of protection) Enclosures With insulating surround: IP40 With door coupling rotary handle: IP66 Terminations Tunnel terminal: IP10 Phase isolator and strip terminal: IP00 Other technical data (sheet catalogue) Weight Temperature dependency, Derating Effective power loss Circuit-breakers Rated current = rated uninterrupted current In = Iu A 160 Rated surge voltage invariability Uimp Main contacts V 8000 Auxiliary contacts V 6000 Rated operational voltage Ue V AC 690 Overvoltage category/pollution degree III/3 Rated insulation voltage Ui V 690 Use in unearthed supply systems V ≦ 690 Switching capacity Rated short-circuit making capacity Icm 240 V Icm kA 187 400/415 V Icm kA 105 440 V 50/60 Hz Icm kA 74 525 V 50/60 Hz Icm kA 53 690 V 50/60 H Ic kA 40 Rated short-circuit breaking capacity Icn Icn Icu to IEC/EN 60947 test cycle O-t-CO Icu kA 240 V 50/60 Hz Icu kA 85 400/415 V 50/60 Hz Icu kA 50 440 V 50/60 Hz Icu kA 35 525 V 50/60 Hz Icu kA 25 690 V 50/60 Hz Icu kA 20 Ics to IEC/EN 60947 test cycle O-t-CO-t-CO Ics kA 240 V 50/60 Hz Ics kA 85 400/415 V 50/60 Hz Ics kA 50 440 V 50/60 Hz Ics kA 35 525 V 50/60 Hz Ics kA 25 690 V 50/60 Hz Ics kA 5 Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit-breaker. Rated short-time withstand current t = 0.3 s Icw kA 1.9 t = 1 s Icw kA 1.9 Utilization category to IEC/EN 60947-2 A Lifespan, mechanical(of which max. 50 % trip by shunt/undervoltage release) Operations 20000 Lifespan, electrical AC-1 400 V 50/60 Hz Operations 10000 415 V 50/60 Hz Operations 10000 690 V 50/60 Hz Operations 7500 Max. operating frequency Ops/h 120 11/01/2022 Eaton 192004 ED2022 V93.0 EN 2 / 5 |
|
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |