24 / 30 page ![]() 9.3.4 Bidirectional and Rail-to-Rail Operation The TMUX7411F, TMUX7412F, and TMUX7413F conduct equally well from source (Sx) to drain (Dx) or from drain (Dx) to source (Sx). Each signal path has very similar characteristics in both directions; however, it is noted that the overvoltage protection is implemented only on the source (Sx) side. The voltage on the drain is only allowed to swing between VDD and VSS and no overvotlage protection is available on the drain side. 9.4 Device Functional Modes The TMUX7411F, TMUX7412F, and TMUX7413F offer two modes of operation (normal mode and fault mode) depending on whether any of the input pins experience an overvoltage condition. 9.4.1 Normal Mode Signals of up to VDD and VSS can be passed through the switch from source (Sx) to drain (Dx) or from drain (Dx) to source (Sx) in normal mode operation. According to Table 8-1, Table 8-2, and Table 8-3 the select pins (SELx) and determines which switch path to turn on. The following conditions must be satisfied for the switch to stay in the ON condition: • The difference between the supples (VDD – VSS) must be higher or equal to 8 V. • The input signals on the source (Sx) or the drain (Dx) must be be between VDD+ VT and VSS – VT. • The select control logic (SELx) must have selected the switch. 9.4.2 Fault Mode The TMUX7411F, TMUX7412F, and TMUX7413F enter into fault mode when any of the input signals on the source (Sx) pins exceed VDD or VSS by a threshold voltage VT. Under the overvoltage condition, the switch input experiencing the fault automatically turns off regardless of the logic status, and the source pin becomes high impedance with negligible amount of leakage current flowing through the switch. When the fault channel is turned-on by the select control logic (SELx), the drain pin (Dx) is pulled to the supply that was exceeded through a 40 kΩ internal resistor. In the fault mode, the general fault flag (FF) is asserted low. The overvoltage protection is provided only for the source (Sx) input pins. The drain (Dx) pin, if used as signal input, must stay in between VDD and VSS at all time since no overvoltage protection is implemented on the drain pin. TMUX7411F, TMUX7412F, TMUX7413F SCDS404 – MARCH 2021 www.ti.com 24 Submit Document Feedback Copyright © 2021 Texas Instruments Incorporated Product Folder Links: TMUX7411F TMUX7412F TMUX7413F |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |