10 / 25 page ![]() TRIO-PS-2G/1AC/12DC/5/C2LPS 106963_en_00 PHOENIX CONTACT 10 / 25 Surge current loads (surge) EN 61000-4-5 Input 1 kV (Test Level 3 - symmetrical) 2 kV (Test Level 3 - asymmetrical) 3 kV (Test Level 4 - symmetrical) 6 kV (Test Level 4 - asymmetrical) Output 0.5 kV (Test Level 2 - symmetrical) 0.5 kV (Test Level 1 - asymmetrical) 1 kV (Test Level 3 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Signal 0.5 kV (Test Level 1 - asymmetrical) 1 kV (Test Level 2 - asymmetrical) Comments Criterion B Criterion A Conducted interference EN 61000-4-6 Input/Output/Signal asymmetrical asymmetrical Frequency range 0.15 MHz ... 80 MHz 0.15 MHz ... 80 MHz Voltage 10 V (Test Level 3) 10 V (Test Level 3) Comments Criterion A Criterion A Voltage dips EN 61000-4-11 Input voltage ( 230 V AC , 50 Hz ) Voltage dip on 70 % , 25 periods ( Test Level 2 ) 70 % , 25 periods ( Test Level 2 ) Comments Criterion C Criterion A Voltage dip on 40 % , 10 periods ( Test Level 2 ) 40 % , 10 periods ( Test Level 2 ) Comments Criterion C Criterion A Voltage dip on 0 % , 1 period ( Test Level 2 ) 0 % , 1 period ( Test Level 2 ) Comments Criterion B Criterion A Immunity according to EN 61000-6-1 (residential), EN 61000-6-2 (industrial) CE basic standard Minimum normative requirements of EN 61000- 6-2 (CE) (immunity for industrial environments) Higher requirements in practice (covered) Key Criterion A Normal operating behavior within the specified limits. Criterion B Temporary impairment to operational behavior that is corrected by the device itself. Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. Emitted interference in acc. with EN 61000-6-3 Radio interference voltage in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |