| Moteur de recherche de fiches techniques de composants électroniques |
|
LTC3589-1 Fiches technique(PDF) 29 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC3589-1 Fiches technique(HTML) 29 Page - Linear Technology |
|
29 / 38 page ![]() LTC3676/LTC3676-1 29 3676ff For more information www.linear.com/LTC3676 operaTion REG NAME B[7] B[6] B[5] B[4] B[3] B[2] B[1] B[0] DEFAULT 0x01 BUCK1 Enable: 0 = Disabled if EN_B1 Low 1 = Enabled Mode: 00 = Pulse-Skipping 01 = Burst 10 = Forced Continuous Start-Up: 0 = Enable at Any Output Voltage 1 = Enable Only if Output <300mV Phase Select: 0 = Clock Phase 1 1 = Clock Phase 2 Clock Rate: 0 = 2.25MHz 1 = 1.125MHz Keep Alive Buck1: 0 = Do Not Keep Alive 1= Keep Alive in Shutdown. Switch DV/DT Control: 0 = Slow 1 = Fast 0000 0000 0x02 BUCK2 Enable: 0 = Disabled if EN_B2 Low 1 = Enabled Mode: 00 = Pulse-Skipping 01 = Burst 10 = Forced Continuous Start-Up: 0 = Enable at Any Output Voltage 1 = Enable Only if Output <300mV Phase Select: 0 = Clock Phase 1 1 = Clock Phase 2 Clock Rate: 0 = 2.25MHz 1 = 1.125MHz Keep Alive Buck2: 0 = Do Not Keep Alive 1 = Keep Alive in Shutdown Switch DV/DT Control: 0 = Slow 1 = Fast 0000 0000 0x03 BUCK3 Enable: 0 = Disabled if EN_B3 Low 1 = Enabled Mode: 00 = Pulse-Skipping 01 = Burst 10 = Forced Continuous Start-Up: 0 = Enable at Any Output Voltage 1 = Enable Only if Output <300mV Phase Select: 0 = Clock Phase 1 1 = Clock Phase 2 Clock Rate: 0 = 2.25MHz 1 = 1.125MHz Keep Alive Buck3: 0 = Do Not Keep Alive 1 = Keep Alive in Shutdown Switch DV/DT Control: 0 = Slow 1 = Fast 0000 0000 0x04 BUCK4 Enable: 0 = Disabled if EN_B4 Low 1 = Enabled Mode: 00 = Pulse-Skipping 01 = Burst 10 = Forced Continuous Start-Up: 0 = Enable at Any Output Voltage 1 = Enable Only if Output <300mV Phase Select: 0 = Clock Phase 1 1 = Clock Phase 2 Clock Rate: 0 = 2.25MHz 1 = 1.125MHz Keep Alive Buck4: 0 = Do Not Keep Alive 1 = Keep Alive in Shutdown Switch DV/DT Control: 0 = Slow 1 = Fast 0000 0000 0x05 LDOA Reserved Reserved Enable LDO3: 0 = Disabled if EN_L3 Low 1 = Enabled Start-Up LDO3: 0 = Enable at Any Output Voltage 1 = Enable Only if Output <300mV Keep Alive LDO3: 0 = Do Not Keep Alive 1 = Keep Alive in Shutdown. Enable LDO2: 0 = Disabled if EN_L2 Low 1 = Enabled Start-Up LDO2: 0 = Enable at Any Output Voltage 1 = Enable Only if Output <300mV Keep Alive LDO2: 0 = Do Not Keep Alive 1 = Keep Alive in Shutdown XX00 0000 0x06 LDOB Reserved Reserved Reserved LTC3676-1 LDO4 Output Voltage: 00 = 1.2V 01 = 2.5V 10 = 2.8V 11 = 3.0V Enable LDO4: 0 = Disabled if EN_L4 Low 1 = Enabled Start-Up LDO4: 0 = Enable at Any Output Voltage 1 = Enable Only if Output <300mV Keep Alive LDO4: 0 = Do Not Keep Alive 1 = Keep Alive in Shutdown XX00 0000 0x07 SQD1 Sequence Down Buck4: 00 = With WAKE 01 = WAKE + 100ms 10 = WAKE + 200ms 11 = WAKE + 300ms Sequence Down Buck3: 00 = With WAKE 01 = WAKE + 100ms 10 = WAKE + 200ms 11 = WAKE + 300ms Sequence Down Buck2: 00 = With WAKE 01 = WAKE + 100ms 10 = WAKE + 200ms 11 = WAKE + 300ms Sequence Down Buck1: 00 = With WAKE 01 = WAKE + 100ms 10 = WAKE + 200ms 11 = WAKE + 300ms 0000 0000 Table 20. LTC3676 Command Registers |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |