5 / 14 page ![]() AN934 Methodology Doc ID 6393 Rev 4 5/14 The calibration byte occupies the five lower order bits in the control register, as shown in Figure 4. These bits represent the binary value between 0 and 31. Table 1 on page 6 shows how many seconds (or ppm) each bit represents in real time for the TIMEKEEPER® product line. The sixth bit is a sign bit. A binary '1' indicates a positive calibration (added pulses), and a binary '0' indicates a negative calibration (blanked pulses). Calibration occurs within a 64- minute cycle. The first 62 minutes in the cycle may, once per minute, have one second either shortened by 128 or lengthened by 256 oscillator cycles. If a binary '1' is loaded into the register, only the first 2 minutes in the 64-minute cycle are modified; if a binary “6” is loaded, the first 12 minutes are affected, and so on. Therefore, each calibration step has the effect of adding 512 or subtracting 256 oscillator cycles for every 125,829,120 actual oscillator cycles (64 minutes x 60 seconds/minute x 32,768 cycles/second). That is, +4.068 or –2.034 ppm of adjustment per calibration step in the calibration register. Assuming that the oscillator is running exactly at 32.768kHz, each of the 31 increments in the calibration byte represent +10.7 or –5.35 seconds per month, which corresponds to a total range of +5.5 or –2.75 minutes per month. As can be seen from Figure 1 on page 1, the peak of the curve corresponds to approximately 25 °C. This is known as the “turnover temperature.” As the temperature rises or falls from room temperature, the oscillator slows down. Typically the turnover point on the graph is very close to 32.768 kHz (no error). However, variations from one crystal to another may cause the turnover point to be slightly above or below 32.768 kHz. The frequency variation for an uncalibrated device is a function of the crystal frequency variation for the given load capacitance (CL). Thus, if the crystal has a CL that is different from the actual internal load capacitance of the device, then the oscillator frequency will run faster or slower than the 32.768 kHz (±1 Hz). At STMicroelectronics, the real-time clock has an internal capacitance of 12.5 pF (except for the M41T6x series, which has an internal capacitance of 6 pF) across the crystal input pins. For this reason, the calibration feature can be programmed to adjust for both negative and positive variations. Entering a value into the 6-bit calibration field of the control register will shift the entire curve up or down according to the values found in Table1 on page6. Figure 4. Control register 1. x = W (Parallel device); OUT (Serial device) 2. y = R (Parallel device); FT (Serial device) d4 d5 d6 d7 d3 d2 y (2) Sign Bit Calibration Value AI05651 S x (1) d0 d1 |
|
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |