| Moteur de recherche de fiches techniques de composants électroniques |
|
L6480 Fiches technique(PDF) 25 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L6480 Fiches technique(HTML) 25 Page - STMicroelectronics |
|
25 / 73 page ![]() L6480 Functional description Doc ID 023278 Rev 3 25/73 The SoftHiZ command causes the motor to decelerate with a programmed deceleration value until the MIN_SPEED value is reached and then forces the bridges into high impedance state (no holding torque is present). The HardHiZ command instantly forces the bridges into high impedance state (no holding torque is present). 6.7.5 Step-clock mode In Step-clock mode the motor motion is defined by the step-clock signal applied to the STCK pin. At each step-clock rising edge, the motor is moved one microstep in the programmed direction and absolute position is consequently updated. When the system is in Step-clock mode the SCK_MOD flag in the STATUS register is raised, the SPEED register is set to zero and motor status is considered stopped regardless of the STCK signal frequency (the MOT_STATUS parameter in the STATUS register equal to “00”). 6.7.6 GoUntil and ReleaseSW commands In most applications the power-up position of the stepper motor is undefined, so an initialization algorithm driving the motor to a known position is necessary. The GoUntil and ReleaseSW commands47 can be used in combination with external switch input (see Section 6.14) to easily initialize the motor position. The GoUntil command makes the motor run at target constant speed until the SW input is forced low (falling edge). When this event occurs, one of the following actions can be performed: ● ABS_POS register is set to zero (home position) and the motor decelerates to zero speed (as a SoftStop command) ● ABS_POS register value is stored in the MARK register and the motor decelerates to zero speed (as a SoftStop command). If the SW_MODE bit of the CONFIG register is set to ‘0’, the motor does not decelerate but it immediately stops (as a HardStop command). The ReleaseSW command makes the motor run at a programmed minimum speed until the SW input is forced high (rising edge). When this event occurs, one of the following actions can be performed: ● ABS_POS register is set to zero (home position) and the motor immediately stops (as a HardStop command) ● ABS_POS register value is stored in the MARK register and the motor immediately stops (as a HardStop command). If the programmed minimum speed is less than 5 step/s, the motor is driven at 5 step/s. 6.8 Internal oscillator and oscillator driver The control logic clock can be supplied by the internal 16-MHz oscillator, an external oscillator (crystal or ceramic resonator) or a direct clock signal. |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |