| Moteur de recherche de fiches techniques de composants électroniques |
|
MCP9808 Fiches technique(PDF) 14 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
MCP9808 Fiches technique(HTML) 14 Page - Microchip Technology |
|
14 / 52 page ![]() MCP9808 DS25095A-page 14 © 2011 Microchip Technology Inc. 4.1.4 ADDRESS BYTE Following the Start condition, the host must transmit an 8-bit address byte to the MCP9808. The address for the MCP9808 temperature sensor is ‘0011,A2,A1,A0’ in binary, where the A2, A1 and A0 bits are set externally by connecting the corresponding pins to VDD ‘1’ or GND ‘0’. The 7-bit address, transmitted in the serial bit stream, must match the selected address for the MCP9808 to respond with an ACK. Bit 8 in the address byte is a read/write bit. Setting this bit to ‘1’ commands a read operation, while ‘0’ commands a write operation (see Figure 4-1). FIGURE 4-1: Device Addressing. 4.1.5 DATA VALID After the Start condition, each bit of data in the transmission needs to be settled for a time specified by tSU-DATA before SCL toggles from low-to-high (see the Sensor Serial Interface Timing Specifications section). 4.1.6 ACKNOWLEDGE (ACK/NAK) Each receiving device, when addressed, must generate an ACK bit after the reception of each byte. The master device must generate an extra clock pulse for ACK to be recognized. The Acknowledging device pulls down the SDA line for tSU-DATA before the low-to-high transition of SCL from the master. SDA also needs to remain pulled down for tH-DATA after a high-to-low transition of SCL. During read, the master must signal an End-of-Data (EOD) to the slave, by not generating an ACK bit (NAK), once the last bit has been clocked out of the slave. In this case, the slave will leave the data line released to enable the master to generate the Stop condition. 4.1.7 TIME-OUT If the SCL stays low or high for the time specified by tOUT, the MCP9808 temperature sensor resets the serial interface. This dictates the minimum clock speed as outlined in the specification. 1 234 5678 9 SCL SDA 01 1 A2 A1 A0 Start Address Byte Slave Address R/W MCP9808 Response Code Address A C K 0 See Table 3-2. |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |