| Moteur de recherche de fiches techniques de composants électroniques |
|
LTC3589 Fiches technique(PDF) 35 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC3589 Fiches technique(HTML) 35 Page - Linear Technology |
|
35 / 50 page ![]() LTC3589/LTC3589-1/ LTC3589-2 35 3589fe Figure 17. IRQ and IRQSTAT Status Register Fault Timing IRQ IRQSTAT CLIRQ 3589 F17 TSD, UV, OR PGOOD FAULT 1 SEC 1 SEC Figure 19. LTC3589 I2C Serial Port Multiple Write Pattern 1 2 34567 8 9 0 1 1 0 1 0 0 WR S7 S6 S5 S4 S3 S2 S1 S0 D7 D6 D5 D4 D3 D2 D1 D0 S7 S6 S5 S4 S3 S2 S1 S0 D7 D6 D5 D4 D3 D2 D1 D0 1 2 34567 8 9 1 2 34567 8 9 1 2 34567 8 9 1 2 34567 8 9 SCL ADDRESS SUB ADDRESS DATA SUB ADDRESS DATA 3589 F19 ACK ACK ACK ACK ACK 0 11 0 0 0 0 1 START SDA STOP Figure 18. LTC3589 I2C Timing tSU, DAT tHD, STA tHD, DAT SDA SCL tHD, STA tHD, STA tSU, STO 3589 F18 tBUF tLOW tHIGH START CONDITION REPEATED START CONDITION STOP START tr tf tSP OPERATION Figure 17 shows the timing of the IRQ pin and IRQSTAT status register following a fault induced hard shutdown event. When a fault occurs, IRQ is latched LOW and bit IRQSTAT[3], IRQSTAT[5], or IRQSTAT[7] is set. IRQ re- mains LOW until the CLIRQ command is issued. When the CLIRQ command has been issued, the IRQSTAT status bit remains set for the one second enable inhibit time or as long as the fault condition persists, whichever is longer. Fault Induced Shutdown Any of the three fault conditions will initiate a hard reset shutdown triggering the following events: 1) A bit corre- sponding to the fault is set in status register IRQSTAT, 2) IRQ and WAKE pins are pulled LOW, 3) enable pin inputs are ignored and the regulators are disabled, 4) all enable bits and software control mode bit in the output voltage enable OVEN command register are cleared, and 5) the pushbutton controller is sent to the PDN state for one second and then to POFF. Re-enabling of regulators is inhibited until both the fault condition and the one second time out have passed to allow regulator outputs sufficient time to discharge. When one second timeout and the fault condition are both passed, if PWR_ON is HIGH, WAKE will come up and the LTC3589 will respond to any enable pins that are also HIGH. |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |