12 / 16 page ![]() www.SiliconStandard.com 12 of 16 SS8017 Rev.2.01 6/06/2003 Table 4. Command-Byte Bit Assignments REGISTER COMMAND POR STATE FUNCTION RRTE2 00h 0000 0000b Read 2nd remote temperature: returns latest temperature RRTE1 01h 0000 0000b Read 1st remote temperature: returns latest temperature RSL 02h N/A Read status byte (flags, busy signal) RCL 03h 0000 0000b Read configuration byte RCRA 04h 0000 0010b Read conversion rate byte RRHI2 05h 0111 1111b (127) Read 2nd remote THIGH limit RRLS2 06h 1100 1001b(-55) Read 2nd remote TLOW limit RRHI1 07h 0111 1111b (127) Read 1st remote THIGH limit RRLS1 08h 1100 1001b (-55) Read 1st remote TLOW limit WCA 09h N/A Write configuration byte WCRW 0Ah N/A Write conversion rate byte WRHA2 0Bh N/A Write 2nd remote THIGH limit WRLN2 0Ch N/A Write 2nd remote TLOW limit WRHA1 0Dh N/A Write 1st remote THIGH limit WRLN1 0Eh N/A Write 1st remote TLOW limit OSHT 0Fh N/A One-shot command (use send-byte format) TCRIT1 35h 0110 1100b (108) Critical temperature for 1 st remote temperaure sensor TCRIT2 36h 0101 1000b (88) Critical temperature for 2 nd remote temperaure sensor The Alert Response can activate several different slave devices simultaneously, similar to the SMBus General Call. If more than one slave attempts to respond, bus arbitration rules apply, and the device with the lower address code wins. The losing device does not generate an acknowledge and continues to hold the ALERT line low until serviced (implies that the host interrupt input is level sensitive). Successful reading of the alert response address clears the inter- rupt latch. Command Byte Functions The 8-bit command byte register (Table 4) is the mas- ter index that points to the various other registers within the SS8017. The register's POR state is 0000 0000, so that a Receive Byte transmission (a protocol that lacks the command byte) that occurs immediately after POR returns the current local temperature data. The one-shot command immediately forces a new con- version cycle to begin. In software standby mode ( RUN /STOP bit = high), a new conversion is begun, after which the device returns to standby mode. If a conversion is in progress when a one-shot command is received in auto-convert mode (RUN/STOP bit = low) between conversions, a new conversion begins, the conversion rate timer is reset, and the next automatic conversion takes place after a full delay elapses. Configuration Byte Functions The configuration byte register contents are listed in table 5. Bit 7 (MASK) is used to mask ALERT inter- rupt. Bit 6 (RUN /STOP) is to put the device in software standby mode. Setting bit 5 (DET_FAN) with logic 1 can activate the detection of fan failure. Logic 1 in bit 4 (EN_TH_SHUT) makes thermal shutdown function valid and logic 0 disables this function and keep TH_SHUT pin low. Bit 3~0 forms thermal shutdown fault queue. The number of faults these bits decided are listed in table 6. Thermal Status Byte Functions The thermal status byte register (02h) (Table 6) indi- cates which (if any) temperature thresholds have been exceeded. This byte also indicates whether or not the ADC is converting and whether there is an open circuit in the remote diode DXPx-DXN path. After POR, the normal state of all the flag bits is zero, assuming none of the alarm conditions are present. The status byte is cleared by any successful read of the status, unless the fault persists. Note that the ALERT interrupt latch is not automatically cleared when the status flag bit is cleared. When reading the status byte, you must check for in- ternal bus collisions caused by asynchronous ADC timing, or else disable the ADC prior to reading the status byte (via the RUN /STOP bit in the configuration byte). In one-shot mode, read the status byte only after the conversion is complete, which is 150ms max after the one-shot conversion is commanded. |
|
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |