| Moteur de recherche de fiches techniques de composants électroniques |
|
AFP02113C Fiches technique(PDF) 17 Page - Panasonic Semiconductor |
|
|
|||||||||||||||||||||||||||||
AFP02113C Fiches technique(HTML) 17 Page - Panasonic Semiconductor |
|
17 / 20 page ![]() SPECIFICATIONS PRODUCT TYPES Control units Product name Built-in memory (Program capacity) Specications Part number Number of I/O points Power supply voltage Input Output Connection type FP0R-C10 Control Unit Relay: 2 A Relay: 2 A Relay: 2 A Relay: 2 A Terminal block Molex connector Molex connector Molex connector Molex connector AFP0RC10RS AFP0RC10RM AFP0RC10CRS AFP0RC10CRM AFP0RC14RS AFP0RC14RM AFP0RC14CRS AFP0RC14CRM AFP0RC32T AFP0RC32MT AFP0RT32CT AFP0RT32CP AFP0RF32MT AFP0RF32MP AFP0RE8X AFP0RE8RS AFP0RE8RM AFP0RE8YRS AFP0RE8YT AFP0RE16X AFP0RE16RS AFP0RE16RM AFP0RE16T AFP0RE16YT AFP0RE32T MIL connector MIL connector MIL connector MIL connector MIL connector MIL connector FP0R-C10 Control Unit with RS232C port Relay: 2 A Terminal block FP0R-C14 Control Unit Relay: 2 A Terminal block FP0R-C14 Control Unit with RS232C port Relay: 2 A Terminal block MIL connector MIL connector MIL connector MIL connector MIL connector MIL connector AFP0RC16T AFP0RC16P AFP0RC16CP AFP0RC32P AFP0RC32MP AFP0RC16CT FP0R-C16 Control Unit FP0R-C16 Control Unit with RS232C port FP0R-C32 Control Unit FP0R-C32 Control Unit with RS485 port FP0R-T32 Control Unit with RS232C port and Real-time clock function FP0R-F32 Control Unit with RS485 port and Battery-less automatic all data backup function EEPROM (32 k steps) EEPROM (32 k steps) EEPROM (32 k steps) EEPROM (16 k steps) EEPROM (16 k steps) EEPROM (16 k steps) EEPROM (16 k steps) EEPROM (16 k steps) EEPROM (16 k steps) 32 32 32 16 16 16 8 8 8 8 Input: 8 Output: 8 Output: 8 Input: 16 Input: 8 Output: 8 Input: 8 Output: 8 Output: 16 Input: 16 Output: 16 Input: 4 Output: 4 16 16 16 14 14 10 10 Input: 16 Output: 16 Input: 16 Output: 16 Input: 16 Output: 16 Input: 8 Output: 8 Input: 8 Output: 8 Input: 8 Output: 6 Input: 8 Output: 6 Input: 6 Output: 4 Input: 6 Output: 4 24 V DC 24 V DC Sink/Source (±common) AFP0RT32MT AFP0RT32MP MIL connector FP0R-T32 Control Unit with RS485 port and Real-time clock function EEPROM (32 k steps) 32 Input: 16 Output: 16 24 V DC 24 V DC Sink/Source (±common) 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC Sink/Source (±common) AFP0RC32CT MIL connector AFP0RC32CP FP0R-C32 Control Unit with RS232C port EEPROM (32 k steps) 32 Input: 16 Output: 16 24 V DC 24 V DC Sink/Source (±common) 24 V DC Sink/Source (±common) 24 V DC Sink/Source (±common) MIL connector AFP0RC16MP AFP0RC16MT FP0R-C16 Control Unit with RS485 port EEPROM (16 k steps) 16 Input: 8 Output: 8 24 V DC 24 V DC Sink/Source (±common) 24 V DC Sink/Source (±common) 24 V DC Sink/Source (±common) AFP0RC14MRS FP0R-C14 Control Unit with RS485 port Relay: 2 A Terminal block EEPROM (16 k steps) 14 Input: 8 Output: 6 24 V DC 24 V DC Sink/Source (±common) 24 V DC Sink/Source (±common) 24 V DC Sink/Source (±common) AFP0RC10MRS FP0R-C10 Control Unit with RS485 port Relay: 2 A Terminal block EEPROM (16 k steps) 10 Input: 6 Output: 4 24 V DC 24 V DC Sink/Source (±common) 24 V DC Sink/Source (±common) Transistor NPN: 0.3 A Transistor NPN: 0.3 A Transistor NPN: 0.3 A Transistor NPN: 0.3 A 24 V DC Sink/Source (±common) 24 V DC Sink/Source (±common) 24 V DC Sink/Source (±common) 24 V DC Sink/Source (±common) 24 V DC Sink/Source (±common) 24 V DC Sink/Source (±common) EEPROM (32 k steps) 32 Input: 16 Output: 16 24 V DC 24 V DC 24 V DC 24 V DC Sink/Source (±common) AFP0RF32CT AFP0RF32CP MIL connector FP0R-F32 Control Unit with RS232C port and Battery-less automatic all data backup function EEPROM (32 k steps) 32 Input: 16 Output: 16 24 V DC 24 V DC Sink/Source (±common) Expansion units Product name Specications Part number Number of I/O points Input Output Connection type FP0R-E8 Expansion Unit — — Terminal block Terminal block Terminal block Molex connector Molex connector 24 V DC — — — AFP0RE8YP MIL connector 8 Output: 8 Transistor PNP: 0.3 A — — FP0R-E16 Expansion Unit — — — AFP0RE16P MIL connector Input: 8 Output: 8 16 Transistor PNP: 0.3 A 24 V DC Sink/Source (±common) — — — AFP0RE16YP MIL connector Output: 16 16 Transistor PNP: 0.3 A — — FP0R-E32 Expansion Unit 32 — AFP0RE32P MIL connector Input: 16 Output: 16 Transistor PNP: 0.3 A 24 V DC Sink/Source (±common) 32 — Notes: 1) The relay output type expansion units come with a power cable (part number: AFP0581). (The transistor output type expansion units need no power cable.) 2) The terminal block type relay output units have two terminal blocks (9 pins) made by Phoenix. Use a 2.5 mm 0.10 inch wide screwdriver. Preferably use the specific terminal block screwdriver (part number: AFP0806, Phoenix type code SZS0, 4 x 2.5 mm 0.10 inch) or equivalent. Notes: 1) See page 13 for the “Control unit replacement table” of the existing FP0 control units. 2) A power cable (Part number: AFPG805) is supplied with the control units. 3) The connector type relay output units have two connectors made by Nihon Molex (Molex type code 51067-0900, 9 pins). Use the specific Molex connector press-fit tool (part number: AFP0805, Nihon Molex type code 57189-5000) or equivalent. 4) The transistor output units have a press-fit socket for wire-pressed terminal cable and contacts. Use the press-fit tool (part number: AXY52000FP) for wire-pressed terminal cable. Transistor NPN: 0.2 A Transistor PNP: 0.2 A Transistor NPN: 0.2 A Transistor PNP: 0.2 A Transistor NPN: 0.2 A Transistor PNP: 0.2 A Transistor NPN: 0.2 A Transistor PNP: 0.2 A Transistor NPN: 0.2 A Transistor PNP: 0.2 A Transistor NPN: 0.2 A Transistor PNP: 0.2 A Transistor NPN: 0.2 A Transistor PNP: 0.2 A Transistor NPN: 0.2 A Transistor PNP: 0.2 A Transistor NPN: 0.2 A Transistor PNP: 0.2 A Transistor NPN: 0.2 A Transistor PNP: 0.2 A C10 C14 C16 C32 T32 F32 — — — — — — — — — — FP0-A21 FP0-A80 FP0-A04V FP0-A04I FP0-TC4 FP0-TC8 FP0-CCLS FP0-IOL FP-WEB2 AFP15402 (C-NET adapter) — — — AFP0RE8X AFP0RE8R AFP0RE8YR AFP0RE8YT/P AFP0RE16X AFP0RE16R AFP0RE16T/P AFP0RE16YT/P AFP0RE32T/P ■ I/O Link unit specifications (FP0 Expansion units) ■ CC-Link slave unit specifications (FP0 Expansion units) ■ Power supply unit specifications (FP0 Expansion units) ■ Current consumption Applicable crimp teriminals ■ FPWeb-server2 unit specifications (FP0 Expansion units) Item Specifications Note: This point number is the number of points that can be linked for inputting and outputting via the host PLC and network MEWNET-F. If the output for the I/O link unit error flag is set to ON, this number becomes 63 points (31 input points and 32 output points). Note: Start up may not be possible if a device with a large inrush current is connected even if below the rated current. In such a case, we recommend suppressing the inrush current by inserting a 1 to 2 Ω resister between the power supply unit and the device. Communication method Synchronous method Transmission line Transmission distance (Total distance) Transmission speed (Baud rate) Number of control I/O point per an I/O link unit Remote I/O map allocation Interface Transmission error check Two-wire, half duple Asynchronous method 2-wire cable (Twisted-pair cable or VCTF 0.75 mm2 x 2C equivalent) Max. 700 m 2,297 ft (using twisted-pair cable) Max. 400 m 1,312 ft (using VCTF cable) 0.5 Mbits/s 64 points (Input: 32 points and Output: 32 points) (Note) 32X / 32Y Conforming to RS485 CRC (Cyclic Redumdancy Check) method Communication functions Communication interface RS232C communication Ethernet communication Supported protocol Memory size Setup method RS232C Ethernet conversion (PLC remote programming via Ethernet) E-mail sending function HTTP server function General-purpose communication (Server/Client) PPP server function RS232C terminal block 3-pin: Mainly used for PLC connection RS232C D-Sub 9-pin: Mainly used for Modem connection 100 BASE-TX (RJ45): Used for Ethernet connection Transmission speed: 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bits/s Data length: 7 bits / 8 bits, Parity: Even / Odd / None 100 Mbits/s (100 BASE-TX: RJ45) TCP, UDP, IP, DHCP, FTP, TELNET, HTTP, SMTP, and PPP 148 kB approx. (for storing htm files) Setup using FP Web Configurator Tool 2 1. Communication specifications 100 m 328 ft 160 m 525 ft 400 m 1,312 ft 900 m 2,952 ft 1,200 m 3,937 ft 100 m 328 ft 150 m 492 ft 200 m 656 ft 600 m 1,969 ft 1,200 m 3,937 ft Version Communication method Transmission speed Max. transmission distance (Note) Interface Station type Number of occupied stations CC-Link Ver.1.10 Broadcast polling method 10 Mbits/s, 5 Mbits/s, 2.5 Mbits/s, 625 kbits/s, 156 kbits/s CC-Link cable Ver.1.10 CC-Link cable CC-Link high-performace cable RS485 Remote device station 1 station 10 Mbits/s 5 Mbits/s 2.5 Mbits/s 625 kbits/s 156 kbits/s Length of the multi-drop connected cables at both ends The cable length has restrictions in communication speed, CC-Link version, and dedicated cables to be used. For details concerning the CC-Link, refer to the CC-Link Partner Association. When an FP0 thermocouple unit is used with an FP0 CC-Link slave unit, the measurement accuracy of the thermocouple unit which is installed on the left of the CC-Link slave unit is as shown in the table below. Note: K, J and T R Thermocouple Standard specifications When CC-Link slave unit with a thermocouple unit 0 to 99.9 °C 32 to 211.82 °F 100 to 299.9 °C 212 to 571.82 °F 300 to 1,500 °C 572 to 2,732 °F 0.8 °C 33.44 °F 3 °C 37.4 °F 2.5 °C 36.5 °F 2 °C 35.6 °F 2 °C 35.6 °F 6 °C 42.8 °F 5 °C 41 °F 4 °C 39.2 °F 7.2 mm 0.28 in or less Manufacturer Part number Applicable wiring JST Mfg. Co., Ltd. V1.25-M3 (round type) V1.25-S3A (fork type) V2-M3 (round type) V2-S3A (fork type) 0.35 to 1.65 mm2 AWG #22 to #15 1.04 to 2.00 mm2 AWG #17 to #14 Input Output Protective functions Rated input voltage Variable input voltage range Rated frequency Frequency range Number of phases Inrush current Leakage current Allow able momentary power off time Rated voltage Voltage accuracy Rated current Output current range Ripple voltage Over-current protection Over-voltage protection 100 to 240 V AC 85 to 264 V AC 50/60 Hz 47 to 63 Hz Single-phase 30 A (0 to P) or less, with cold start 0.75 mA or less 10 ms or more 24 V DC ±5 % 0.7 A (Note) 0 to 0.6 A 500 mV or less 0.63 A or more Available Type of unit Control unit current consumption (24 V DC) Expansion unit current consumption (24 V DC) Type of unit Control unit current consumption (24 V DC) Expansion unit current consumption (24 V DC) FP0R control units FP0R expansion units 100 mA or less 120 mA or less 70 mA or less 90 mA or less 10 mA or less 10 mA or less 10 mA or less 15 mA or less 10 mA or less 20 mA or less 20 mA or less 25 mA or less 35 mA or less 50 mA or less 100 mA or less 100 mA or less FP0 intelligent units Communication units 20 mA or less 20 mA or less 20 mA or less 20 mA or less 25 mA or less 40 mA or less 30 mA or less 50 mA or less 100 mA or less 60 mA or less 100 mA or less 130 mA or less 40 mA or less 40 mA or less 95 mA or less (at 24 V DC) 240 mA or less (at 12 V DC) ● Control unit current consumption This refers to the current consumed via the power supply connector of the control unit. If expansion units or intelligent units are added, the current is increased by the value indicated above. ● Expansion unit current consumption This refers to the current consumed via the power supply connector of the expansion unit. Units with no value indication don't have a power supply connector. Item Specifications Item Specifications Item Specifications Power supply voltage 16 17 |
|
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |