| Moteur de recherche de fiches techniques de composants électroniques |
|
AFP02113C Fiches technique(PDF) 4 Page - Panasonic Semiconductor |
|
|
|||||||||||||||||||||||||||||
AFP02113C Fiches technique(HTML) 4 Page - Panasonic Semiconductor |
|
4 / 20 page ![]() Motor (slave) Motor (master) Inverter Encoder High-speed counter Pulse output Conveyor 1 Conveyor 2 POSITIONING NETWORK ■ PLC link (MEWNET-W0) ■ FP Web-Server2 ■ RS485 serial communication ■ RS232C general-purpose serial communications ■ CC-Link slave unit FP0 CC-Link slave unit ■ Built-in 4-axis pulse outputs (Transistor output type) Two sets can simultaneously undergo two-axis linear interpolation. No complicated speed calculation or programming is required. Two-axis linear interpolation is available by using the F175 dedicated instruction. Two sets such as two X-Y tables, for example, can be simultaneously controlled. * The port block has S, R, and G terminals for connection. Operation display panels can also be connected to the tool port. * Both the relay output and transistor output types of control unit equipped with an RS232C port are available. The control unit has an RS232C port for serial communications. The RS232C port allows for direct connection to an operation display panel or a PC. Also, it facilitates bi-directional data communications with bar-code readers and other RS232C devices. Host computer (commercially available PC) Operation display panel FP0R ● For connection with an operation display panel or a PC ● For data communications with general-purpose RS232C devices IMAGECHECKER Bar-code reader ID card management system When 17 or more FP series units need to be linked, you can link up to 99 units by using the Modbus function instead of MEWNET-W0. Since each FP0R unit can be either a master or a slave, a multi-master link can be created by passing a token from a user program. ■ Labelers: Stopping the motion at a constant distance from the point where a label end detection signal is triggered ■ Processing machines: Stopping the motion at a constant distance from the point where a processing object edge detection signal is triggered, and cut/drill the object Compatible with both Modbus master and slave RTU. The motion can be started without a preset target value. When a stop signal is input, the target value is set, and the motion is slowed to a stop. This feature expands applications for the eco-conscious business field, and is ideal for the control of air conditioners, temperature, and electrical power. FP0R The FP0R operation status can be monitored on a Web browser. The FP0R operation status can be monitored on a Web browser by connecting FP Web-Server2 and FP0R via RS232C and making required settings using dedicated software (FP Web Configurator Tool 2). Contact data can be shared among up to 16 PLC units, including FP0R, FPΣ, FP-X, FP2/FP2SH, and a mixture of them, without the need for programs. ■ Jog positioning control (F171instruction) FP0R RS232C FP Web-Server 2 Ethernet 100BASE-TX RS485 / 16 stations / 115.2 kbps / 1200 m 3937 ft Two-axis X-Y table x 2 FP0R INVERTER Y0,Y2,Y4,Y6 COM 5 V Vin Rin GND This unit is compatible with CC-Link, which is an open network, and capable of reading/writing four-word data through a maximum of 16 input and 16 output points. ● Up to 99 units can be connected. FP0R Connectable as slaves CC-Link Ethernet Other companies’ PLC as a master station Connectable with FPΣ, FP-X, FP2/FP2SH as well as FP0R Useful for The speed can be changed during the jog operation. The jog operation (without a preset target value) is continued until the stop signal is input. The positioning operation slows to a stop. FP Web-Server 2 (AFP0611) ■ I/O link unit This link unit enables FP0R to serve as a slave station of MEWNET-F (remote I/O system) and exchange I/O data from 32 input points and 32 output points with a master station without the need for programs. FP0R RS485 / 32 stations / 500 kbps / 700 m 2296 ft 789 789 MW Master station with an FP2 multi-wire link unit (FP2-MW) mounted FP0 I/O link unit FP0R FP0 I/O link unit FP0-IOL (AFP0732) FP0-CCLS (AFP07943) FPΣ, FP-X, and FP2/FP2SH can also be mixed in the network. Start signal Stop signal ■ Labelers: Starting the operation at a relatively low acceleration to prevent tape from breaking Stopping the operation at high deceleration when detecting the label end to save the tape ■ Lifts: Optimizing the acceleration and deceleration during ascending and descending transfers. Use two FP0R units to control the assembly and transfer sections of a small machine respectively, connect them via the PLC link, and share one display The acceleration time and deceleration time can be individually set. ■ Individual settings for acceleration and deceleration (available for F171, F172, and F174 instructions) Individually settable within a range of 30 ms to 32,767 ms Acceleration time Deceleration time ■ Speed synchronization of transfer or processing equipment. The target speed can be changed by an external signal input during the jog operation or trapezoidal control operation. ■ Changing the speed (available for F171 and F172 instructions) ■ Detection of motor rotation speed for encoder feedback control Pulses input in a specified period by a single instruction are counted, and the frequency is calculated. ■ Measuring the pulse frequency (F178 instruction) Setting range: 1 ms to 5,000 ms The speed can be freely changed until the operation starts to decelerate to a stop. ■ High-speed counters and pulse outputs ■ Built-in multipoint PWM outputs (4 channels) Specified period Ladder programs can be combined to create an application for counting pulse signals from the encoder through the high-speed counter input and adjusting the pulse output frequency based on the count to synchronize the slave axis speed with the master axis speed. In the right-hand figure, the speed of conveyor 1, which is inverter-controlled, is measured based on the encoder pulse count, and pulses are output to the slave motor (for jog operation) according to the measured speed in order to synchronize the speed of conveyor 2. The speed can be controlled by changing the ON width of the PWM output. The unit can also serve as an analog voltage output when a smoothing capacitor is inserted in the circuit. The pulse output port of FP0R can also serve as a PWM output port. One of the application examples is an analog voltage output, which can be used for inverter speed control. RS232C RS485 1-to-1 link available Up to 16 units connectable RS232C / 2 stations / 115.2 kbps / 15 m 49.2 ft Application examples Application examples Management of manufacturing line operations Master / Slave Master / Slave Master / Slave Token passing A multi-master link of up to 99 units can be created. Master / Slave Master / Slave Temperature controller Eco-POWER METER PLC MCU Useful for Useful for Useful for 4 5 |
|
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |