23 / 33 page ![]() TIMER A.C. CHARACTERISTICS Definitions : Error = Indicated Time Value - Actual Time Value tpsc = tCLKx Prescale Value Internal Timer Mode Single Interval Error (free running) (note 2) ± 100ns Cumulative Internal Error 0 Error between Two Timer Reads ± (tpsc + 4tCLK) Start Timer to Stop Timer Error + (2tCLK + 100ns) to - (tpsc + 6tCLK + 100ns) Start Timer to Read Timer Error + 0 to – (tpsc + 6t CLK + 400ns) Start Timer to Interrupt Request Error (note 3) - 2t CLK to – (4tCLK + 800ns) Notes : 1. Error may be cumulative if repetitively performed. 2. Error with respect to TOUT or INT if note 3 is true. 3. Assuming it is possible for the timer to make an interrupt request immediately. PULSE WIDTH MEASUREMENT MODE Measurement Accuracy (note 1) + 2tCLK to – (tpsc + 4tCLK) Minimum Pulse Width 4tCLK EVENT COUNTER MODE Minimum Active Time of TAI, TBI 4tCLK Minimum Inactive Time of TAI, TBI 4tCLK MK68901 23/33 |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |