| Moteur de recherche de fiches techniques de composants électroniques |
|
LSM6DSTTR Fiches technique(PDF) 48 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
LSM6DSTTR Fiches technique(HTML) 48 Page - STMicroelectronics |
|
48 / 180 page ![]() Functionality LSM6DST 48/180 DocID033525 Rev 2 6.3 Gyroscope power modes In the LSM6DST, the gyroscope can be configured in four different operating modes: power- down, low-power, normal mode and high-performance mode. The operating mode selected depends on the value of the G_HM_MODE bit in CTRL7_G (16h). If G_HM_MODE is set to '0', high-performance mode is valid for all ODRs (from 12.5 Hz up to 6.66 kHz). To enable the low-power and normal mode, the G_HM_MODE bit has to be set to '1'. Low- power mode is available for lower ODRs (12.5, 26, 52 Hz) while normal mode is available for ODRs equal to 104 and 208 Hz. 6.4 Block diagram of filters Figure 15. Block diagram of filters 6.4.1 Block diagrams of the accelerometer filters In the LSM6DST, the filtering chain for the accelerometer part is composed of the following: Analog filter (anti-aliasing) Digital filter (LPF1) Composite filter Details of the block diagram appear in the following figure. Figure 16. Accelerometer UI chain |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |