5 / 39 page ![]() – – – – 4 5 Figure 4: Electrical Specifications 250 Series Transceiver Specifications Parameter Symbol Min. Typ. Max. Units Notes Interface Section Input Logic Low V I L 0 0.8 VDC Input Logic High V I H 2.0 V CC VDC Output Logic Low V OL I OL = 8.5mA 0.6 VDC I OL = 10µA 0.1 VDC I OL = 25mA 1.0 VDC Output Logic High V OH I OH = -3mA V CC–0.7 VDC I OH = -10µA V CC–0.1 I OH = -10mA V CC-0.8 Flash Specifications (Non-Volatile Registers) Flash Write Duration 16 ms Flash Write Cycles 20k 100k cycles 1. V CC = 3.3V 2. Into a 50-ohm load 3. At 25ºC 4. 26 channels each 5. At 10-3 BER 6. P in = -20dBm, 2 CW interferers, FRF = 915MHz, F 1 = FRF + 3MHz, F2 = FRF + 6MHz, max gain, high-sensitivity 7. Desired signal 3dB above input sensitivity level, CW interferer power level increased until BER = 10-2, +/–1MHz Pin Assignments 1 2 3 4 6 5 7 8 9 10 26 11 PR_PKT TXD NC NC EX CMD_RSP NC C2D RESET NC 23 22 21 20 18 19 17 16 15 14 GND ANT GND RXD RSSI CMD BE NC NC CTS 12 13 25 24 Figure 5: 250 Series Transceiver Pin Assignments (Top View) Pin Descriptions Pin Number Name I/O Description 1 PR_PKT O Processing Packet Indicator. This line goes high when the module is processing a valid or potentially valid packet. 2 TXD O UART Transmit Data Output. This is the output line for the configuration command responses as well as the data received over the air. 3, 4, 5, 8, 17, 18 NC — No Electrical Connection. Do not connect any traces to these lines. 6 RESET I/O Reset line. This line is normally an input that acts as an active low hardware reset line. It does occasionally act as an output, so please see the Reset section for details. 7 C2D — Reserved 9 CMD_RSP O Command Response. This line is low when the data on the TXD line is a response to a command and not data received over the air. 10 EX O Exception Output. A mask can be set to take this line high when an exception occurs. The line is lowered when the exception register is read (regEXCEPTION) 11, 12, 13, 23 GND — Ground 14 RSSI O This line outputs an analog voltage that is proportional to the strength of the incoming signal. 15 CMD I Command Input. This line sets the serial data as either command data to configure the module or packet data to be sent over the air. Pull low for command data; pull high for packet data. 16 BE O Buffer Empty. This line goes high when the UART input buffer is empty, indicating that all data has been transmitted. 19 CTS O UART Clear To Send, active low. This line indicates to the host microcontroller when the module is ready to accept data. When CTS is high, the module is busy. When CTS is low, the module is ready for data. 20 RXD I UART Receive Data Input. This is the input line for the configuration commands as well as data to be sent over the air. 22 ANT — 50-ohm RF Antenna Port 24, 25, 26 VCC — Supply Voltage Figure 6: 250 Series Transceiver Pin Descriptions Pin Descriptions |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |