9 / 39 page ![]() – – – – 12 13 Reset to Factory Default It may be necessary to reset the non-volatile registers to their factory defaults. To reset the module, hold the CMD line low and cycle power to hardware-reset the module. The CMD line must remain low for a minimum of 600ms after resetting the module. Once the CMD line is released, the module’s non-volatile registers are reset to factory defaults. Compatibility Mode The 250 Series modules support a mode that allows them to communicate with the smaller, lower power 25 Series modules. The 250 Series operates at a much narrower receive bandwidth (200kHz) than the 25 Series (600kHz). To allow interoperability, the 250 and 25 Series transceivers support a compatibility mode that allows the modules to communicate effectively with each other. Compatibility mode reduces the maximum RF data rate to 76.8kbps. All UART baud rates are supported, although the RF data rates associated with baud rates 31,250; 38,400; 57,600 and 115,200 are reduced. Automatic Gain Control and Manual Gain Control The gain setting of the receiver’s low noise amplifier (LNA) is adjustable. By default, the 250 Series is factory-configured to use its internal automatic gain control (AGC) circuit to manage receiver sensitivity. Reducing the gain increases the linearity of the receiver, but reduces maximum sensitivity; increasing the gain does the opposite. Generally speaking, higher linearity (increased third order input intercept point, IIP3) gives improved performance in high-interference environments; high gain yields better performance in low-interference environments. The module contains an AGC circuit that manages these settings automatically, and it should be used whenever possible. However, when attempting to make analog RSSI measurements, fixing the LNA gain produces more meaningful results. Digital RSSI readings are internally compensated and may be taken with AGC enabled. Exception Engine The modules are equipped with an internal exception engine. If errors occur during module operation, an exception is raised. Exception codes are stored in the regEXCEPTION register and are cleared once they are read. If an exception code is already present in regEXCEPTION when an error occurs, the new exception code overwrites the old value. Exception Codes Exception codes are organized by type for ease of masking. Figure 9 lists the exception codes and their meanings. All other values are reserved. Exception Masking The EX line can be asserted to indicate to the host that an error has occurred. The exception mask provides a simple method of choosing which errors cause the line to toggle. If the result of ANDing the exception code with the exception mask is non-zero, the EX line is asserted. The regEXCEPTION register must be read to reset the line. Figure 10 lists some example exception masks. The exception mask has no effect on the exceptions stored in the exception register. It only controls which exceptions affect the EX line. 250 Series Transceiver Exception Codes Exception Code Exception Name Description 0x08 EX_BUFOVFL Internal UART buffers overflowed. 0x09 EX_RFOVFL Internal RF packet buffer overflowed. 0x13 EX_WRITEREGFAILED Attempted write to register failed. 0x20 EX_NORFACK Acknowledgement packet not received after maximum number of retries. 0x40 EX_BADCRC Bad CRC detected on incoming packet. 0x42 EX_BADHEADER Bad CRC detected in packet header. 0x43 EX_BADSEQID Sequence ID was incorrect in ACK packet. 0x44 EX_BADFRAMETYPE Unsupported frame type specified. Figure 9: 250 Series Transceiver Exception Codes 250 Series Transceiver Example Exception Masks Exception Mask Exception Name 0x08 Allows only EX_BUFOVFL and EX_RFOVFL to trigger the EX line 0x10 Allows only EX_WRITEREGFAILED to trigger the EX line 0x20 Allows only EX_NORFACK to trigger the EX line 0x40 Allows only EX_BADCRC, EX_BADHEADER, EX_BADSEQID and EX_BADFRAMETYPE exceptions to trigger the EX line 0x60 Allows EX_BADCRC, EX_BADHEADER, EX_BADSEQID, EX_ BADFRAMETYPE and EX_NORFACK exceptions to trigger the EX line 0xFF Allows all exceptions to trigger the EX line Figure 10: 250 Series Transceiver Example Exception Masks |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |