Back Button MV1012SC Datasheet HTML 21Page - Shindengen Electric Mfg.Co.Ltd MV1012SC Datasheet HTML 22Page - Shindengen Electric Mfg.Co.Ltd MV1012SC Datasheet HTML 23Page - Shindengen Electric Mfg.Co.Ltd MV1012SC Datasheet HTML 24Page - Shindengen Electric Mfg.Co.Ltd MV1012SC Datasheet HTML 25Page - Shindengen Electric Mfg.Co.Ltd MV1012SC Datasheet HTML 26Page - Shindengen Electric Mfg.Co.Ltd MV1012SC Datasheet HTML 27Page - Shindengen Electric Mfg.Co.Ltd MV1012SC Datasheet HTML 28Page - Shindengen Electric Mfg.Co.Ltd MV1012SC Datasheet HTML 29Page - Shindengen Electric Mfg.Co.Ltd Next Button
Zoom Inzoom in Zoom Outzoom out
 25 / 33 page
background image
MV1012SC
24
5.2 PWM dimming
5.2.1
PWM dimming in 100% and oscillation off regions
PWM dimming can be performed by sending a PWM signal to the REF pin with VREF in the 100% dimming ratio as the
high level and VREF in the oscillation off region as the low level. Frequency f and on-duty cycle Don of a PWM signal
should be 1 kHz or less and 1% or more, respectively.
Figure 21 Example of PWM dimming operation
As shown in Figure 21, when a PWM signal with on-duty cycle of Don is applied to the REF pin, Io becomes an average
current Io (ave) = Don x Io (max) + (1 – Don) x Io (min). In actual use, Io (min) is very small, and the equation may be
rewritten to Io (ave) ≈ Don x Io (max).
In PWM dimming, if the first switching-on timing in the H-level period is irregular, the practical Don will also become
irregular and Io will become unstable. The effect is especially significant if Don is small. To avoid this problem, the first
switching-on timing in the H-level period of every cycle aligns with each other by detecting a change of VREF from L level to
H level and forcibly outputting an on-trigger. This function helps stabilize Io (ave), even if Don is small.
CAT.No.1A0602-1E



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33


Fiches technique Télécharger

Go To PDF Page


Lien URL



ALLDATASHEET vous a-t-il été utile ?  [ DONATE ] 

À propos de Alldatasheet   |   Publicité   |   Contactez-nous   |   Politique de confidentialité   |   Lien vers la fiche technique    |   Echange de liens   |   Fabricants
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com