MR4530 Fiches technique(PDF) 24 Page - Shindengen Electric Mfg.Co.Ltd

No de pièce MR4530
Description  Partial Resonance Power Supply ICModule
PDF  43 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricant  SHINDENGEN [Shindengen Electric Mfg.Co.Ltd]
Site Internet  http://www.shindengen.co.jp/
Logo SHINDENGEN - Shindengen Electric Mfg.Co.Ltd

MR4530 Fiches technique(HTML) 24 Page - Shindengen Electric Mfg.Co.Ltd

Back Button MR4530 Datasheet HTML 20Page - Shindengen Electric Mfg.Co.Ltd MR4530 Datasheet HTML 21Page - Shindengen Electric Mfg.Co.Ltd MR4530 Datasheet HTML 22Page - Shindengen Electric Mfg.Co.Ltd MR4530 Datasheet HTML 23Page - Shindengen Electric Mfg.Co.Ltd MR4530 Datasheet HTML 24Page - Shindengen Electric Mfg.Co.Ltd MR4530 Datasheet HTML 25Page - Shindengen Electric Mfg.Co.Ltd MR4530 Datasheet HTML 26Page - Shindengen Electric Mfg.Co.Ltd MR4530 Datasheet HTML 27Page - Shindengen Electric Mfg.Co.Ltd MR4530 Datasheet HTML 28Page - Shindengen Electric Mfg.Co.Ltd Next Button
Zoom Inzoom in Zoom Outzoom out
 24 / 43 page
background image
Shindengen Electric MFG.CO.,LTD
- 54 -
6.1.3 Resonating capacitor
(1) Selecting the resonating capacitor
The resonating capacitor must have the following characteristics:
1) The withstand voltage is significantly greater than that of the main switching device.
2) Tangent of loss angle tan
δ is small.
3) The upper temperature limit is high.
Ideally, use a mica or polypropylene capacitor. A low-loss ceramic capacitor should also be adequate. Consult with
the manufacturer before using this capacitor type.
(2) Capacity of resonating capacitor
Noise is reduced by the resonance determined by the resonating capacitor and the primary coil inductance. This
has both favorable and adverse effects, as shown in the table below. Consider these effects when setting the
capacity of the capacitor.
Item
Small
← Capacitor capacity → Large
Efficiency during standby
Increases
Decreases
Heat buildup in the transformer
Decreases
Increases
Ringing voltage at turn-off of main switching device
Increases
Decreases
Noise
Increases
Decreases
Operating frequency
Increases
Decreases
6. Supplementary design information



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43


Fiches technique Télécharger

Go To PDF Page


Lien URL



ALLDATASHEET vous a-t-il été utile ?  [ DONATE ] 

À propos de Alldatasheet   |   Publicité   |   Contactez-nous   |   Politique de confidentialité   |   Lien vers la fiche technique    |   Echange de liens   |   Fabricants
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com