7 / 22 page ![]() 2003 Microchip Technology Inc. Preliminary DS21673C-page 7 24AA515/24LC515/24FC515 5.0 DEVICE ADDRESSING A control byte is the first byte received following the Start condition from the master device (Figure 5-1). The control byte consists of a 4-bit control code; for the 24XX515, this is set as ‘1010’ binary for read and write operations. The next bit of the control byte is the block select bit (B0). This bit acts as the A15 address bit for accessing the entire array. The next two bits of the control byte are the Chip Select bits (A1, A0). The Chip Select bits allow the use of up to four 24XX515 devices on the same bus and are used to select which device is accessed. The Chip Select bits in the control byte must correspond to the logic levels on the corresponding A1 and A0 pins for the device to respond. These bits are in effect the two Most Significant bits of the word address. The last bit of the control byte defines the operation to be performed. When set to a one, a read operation is selected, and when set to a zero, a write operation is selected. The next two bytes received define the address of the first data byte (Figure 5-2). Because only A14…A0 are used, the upper address bit is a don’t care. The upper address bits are transferred first, followed by the less significant bits. Following the Start condition, the 24XX515 monitors the SDA bus checking the device type identifier being transmitted. Upon receiving a ‘1010’ code and appro- priate device select bits, the slave device outputs an Acknowledge signal on the SDA line. Depending on the state of the R/W bit, the 24XX515 will select a read or write operation. This device has an internal addressing boundary limitation that is divided into two segments of 256K bits. Block select bit ‘B0’ is used in place of address bit location ‘A15’ to control access to each segment. FIGURE 5-1: CONTROL BYTE FORMAT 5.1 Contiguous Addressing Across Multiple Devices The Chip Select bits A1, A0 can be used to expand the contiguous address space for up to 2 Mbit by adding up to four 24XX515's on the same bus. In this case, software can use A0 of the control byte as address bit A16 and A1 as address bit A17. It is not possible to sequentially read across device boundaries. Each device has internal addressing boundary limitations. This divides each part into two segments of 256K bits. The block select bit ‘B0’ controls access to each “half” rather than address bit location A15. Sequential read operations are limited to 256K blocks. To read through four devices on the same bus, eight random Read commands must be given. FIGURE 5-2: ADDRESS SEQUENCE BIT ASSIGNMENTS 1 0 1 0 B0 A1 A0 SACK R/W Control Code Chip Select Bits Slave Address Acknowledge Bit Start Bit Read/Write Bit 1 010 B 0 A 1 A 0 R/W X A 11 A 10 A 9 A 7 A 0 A 8 •• • • •• A 12 CONTROL BYTE ADDRESS HIGH BYTE ADDRESS LOW BYTE CONTROL CODE CHIP SELECT BITS X = Don’t Care Bit A 13 A 14 BLOCK SELECT BIT |
|
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |