| Moteur de recherche de fiches techniques de composants électroniques |
|
AN2281 Fiches technique(PDF) 19 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN2281 Fiches technique(HTML) 19 Page - STMicroelectronics |
|
19 / 38 page ![]() AN2281 Library parameters 19/38 With the purpose of avoiding too strong a response by the PI regulator at the end of the motor start-up, when the error between target speed and measured speed could be high, PI regulation is enabled (and ramp-up ended) if, during the voltage ramp-up the actual speed of the rotor is higher than an established threshold speed defined by: #define CL_SPEED_VALIDATION xxx // in rpm The control system, therefore, starts the motor as already described for open loop and it enables the PI regulator either at the end of the start-up or when rotor reaches the speed CL_SPEED_VALIDATION. Figure 14 summarizes the closed loop start-up strategy. Figure 14. Closed loop start-up with (b) and without (a) rotor alignment phase |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |