| Moteur de recherche de fiches techniques de composants électroniques |
|
GMS90C320PL40 Fiches technique(PDF) 29 Page - Hynix Semiconductor |
|
|
|||||||||||||||||||||||||||||
GMS90C320PL40 Fiches technique(HTML) 29 Page - Hynix Semiconductor |
|
29 / 46 page ![]() GMS90C320 OCT. 2000 Ver 1.2 25 AC Characteristics Explanation of the AC Symbols Each timing symbol has 5 characters. The first character is always a ‘t’ (stand for time). The other characters, depending on their positions, stand for the name of a signal or the logical status of that signal. The following is a list of all the characters and what they stand for. A: Address C: Clock D: Input Data H: Logic level HIGH I: Instruction (program memory contents) L: Logic level LOW, or ALE P: PSEN Q: Output Data R: RD signal T: Time V: Valid W: WR signal X: No longer a valid logic level Z: Float For example, tAVLL = Time from Address Valid to ALE Low tLLPL = Time from ALE Low to PSEN Low |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |