| Moteur de recherche de fiches techniques de composants électroniques |
|
LBA120 Fiches technique(PDF) 3 Page - Clare, Inc. |
|
|
|||||||||||||||||||||||||||||
LBA120 Fiches technique(HTML) 3 Page - Clare, Inc. |
|
3 / 8 page ![]() LBA120 www.clare.com Rev. 5 PERFORMANCE DATA* The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. 3 LBA120 Typical LED Forward Voltage Drop (N=50 Ambient Temperature = 25 °C; IF = 5mADC) 35 30 25 20 15 10 5 0 1.17 1.19 1.21 1.23 1.25 LED Forward Voltage Drop (V) LBA120 - FormA Typical On-Resistance Distribution (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC, IF=5mADC) 35 30 25 20 15 10 5 0 8.45 9.05 9.65 10.25 8.75 9.35 9.95 On-Resistance ( Ω) LBA120 - FormB Typical On-Resistance Distribution (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC, IF=5mADC) 30 25 20 15 10 5 0 9.25 11.05 12.85 14.65 10.15 11.95 13.75 On-Resistance ( Ω) LBA120 - FormA Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25 °C) 35 30 25 20 15 10 5 0 330 350 370 390 340 360 380 Blocking Voltage (V) LBA120 - FormB Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25 °C) 30 25 20 15 10 5 0 263 297 331 365 280 314 348 Blocking Voltage (V) LBA120 - FormA Typical IF for Switch Operation (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC) LED Current (mA) 25 20 15 10 5 0 0.3 0.7 1.1 0.1 0.5 0.9 1.3 LBA120 - FormB Typical IF for Switch Operation (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC) 30 25 20 15 10 5 0 0.24 0.32 0.48 0.64 0.40 LED Current (mA) 0.56 LBA120 - FormA Typical IF for Switch Dropout (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC) 25 20 15 10 5 0 0.3 0.7 1.1 0.1 0.5 0.9 1.3 LED Current (mA) LBA120 - FormB Typical IF for Switch Dropout (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC) 25 20 15 10 5 0 0.24 0.40 0.56 0.16 0.32 0.48 0.64 LED Current (mA) LBA120 - FormA Typical Turn-On Time (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC; IF = 5mADC) 0.66 1.14 1.86 0.90 1.38 Turn-On (ms) 25 20 15 10 5 0 1.62 LBA120 - FormB Typical Turn-On Time (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC; IF = 5mADC) 0.04 0.20 0.36 0.12 0.28 0.44 Turn-On (ms) 30 25 20 15 10 5 0 LBA120 - FormA Typical Turn-Off Time (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC; IF = 5mADC) 0.16 0.08 0.32 0.23 0.40 0.24 Turn-Off (ms) 25 20 15 10 5 0 |
|
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |