4 / 16 page ![]() AD8418 Data Sheet ABSOLUTE MAXIMUM RATINGS Table 3. Parameter Rating Supply Voltage 6 V Input Voltage Range Continuous −2 V to +70 V Survival −4 V to +85 V Differential Input Survival ±5.5 V Reverse Supply Voltage 0.3 V ESD Human Body Model (HBM) ±2000 V Operating Temperature Range −40°C to +125°C Storage Temperature Range −65°C to +150°C Output Short-Circuit Duration Indefinite Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. ESD CAUTION Rev. 0 | Page 4 of 16 |
|
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|