| Moteur de recherche de fiches techniques de composants électroniques |
|
ADE7753ARS Fiches technique(PDF) 11 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE7753ARS Fiches technique(HTML) 11 Page - Analog Devices |
|
11 / 60 page ![]() ADE7753 Rev. C | Page 11 of 60 TYPICAL PERFORMANCE CHARACTERISTICS FULL-SCALE CURRENT (%) 0.1 –0.5 –0.1 –0.2 –0.3 –0.4 0.2 0.1 0.5 0.4 0.3 0 1 10 100 02875-0-006 +85°C, PF = 0.5 +25°C, PF = 0.5 GAIN = 1 INTEGRATOR OFF INTERNAL REFERENCE +25°C, PF = 1 –40°C, PF = 0.5 Figure 6. Active Energy Error as a Percentage of Reading (Gain = 1) over Power Factor with Internal Reference and Integrator Off FULL-SCALE CURRENT (%) 0.1 –0.4 –0.2 –0.1 –0.3 0.1 0.4 0.3 0.2 0 1 10 100 02875-0-008 +25°C, PF = 1 GAIN = 8 INTEGRATOR OFF INTERNAL REFERENCE –40°C, PF = 1 +85°C, PF = 1 Figure 7. Active Energy as a Percentage of Reading (Gain = 8) over Temperature with Internal Reference and Integrator Off FULL-SCALE CURRENT (%) 0.1 –0.6 –0.2 –0.4 0.2 0.8 0.6 0.4 0 1 10 100 02875-0-009 +85°C, PF = 0.5 GAIN = 8 INTEGRATOR OFF INTERNAL REFERENCE –40°C, PF = 0.5 +25°C, PF = 1 +25°C, PF = 0.5 Figure 8. Active Energy Error as a Percentage of Reading (Gain = 8) over Power Factor with Internal Reference and Integrator Off FULL-SCALE CURRENT (%) 0.1 –0.3 –0.1 –0.2 0.1 0.3 0.2 0 1 10 100 GAIN = 8 INTEGRATOR OFF EXTERNAL REFERENCE +85°C, PF = 1 02875-0-010 –40°C, PF = 1 +25°C, PF = 1 Figure 9. Active Energy Error as a Percentage of Reading (Gain = 8) over Temperature with External Reference and Integrator Off FULL-SCALE CURRENT (%) 0.1 –0.6 –0.2 –0.4 0.2 0.6 0.4 0 1 10 100 GAIN = 8 INTEGRATOR OFF EXTERNAL REFERENCE +85°C, PF = 0.5 02875-0-011 –40°C, PF = 0.5 +25°C, PF = 0.5 +25°C, PF = 1 Figure 10. Active Energy Error as a Percentage of Reading (Gain = 8) over Power Factor with External Reference and Integrator Off FULL-SCALE CURRENT (%) 0.1 –0.5 –0.1 –0.2 –0.3 –0.4 0.2 0.1 0.5 0.4 0.3 0 1 10 100 02875-0-012 +85°C, PF = 0.5 +25°C, PF = 0.5 GAIN = 1 INTEGRATOR OFF INTERNAL REFERENCE +25°C, PF = 0 –40°C, PF = 0.5 Figure 11. Reactive Energy Error as a Percentage of Reading (Gain = 1) over Power Factor with Internal Reference and Integrator Off |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |