| Moteur de recherche de fiches techniques de composants électroniques |
|
AJ71QC24N-R2 Fiches technique(PDF) 23 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
AJ71QC24N-R2 Fiches technique(HTML) 23 Page - Omron Electronics LLC |
|
23 / 24 page ![]() EJ1 23 I/O Devices Examples of EJ1-series Temperature Controllers/Output Devices SW2 SW1 ERROR OCC SD/RD READY G3ZA SSR SSR Eight Units max. ∗ SSR SSR COM1 COM2 COM3 PWR RUN ERR ALM SW1 ON SW2 EJ1-TC2 BCDE COM1 COM2 COM3 PWR RUN ERR ALM SW1 ON SW2 EJ1-TC2 BCDE COM1 COM2 COM3 PWR RUN ERR ALM SW1 ON SW2 EJ1-TC2 BCDE COM1 COM2 COM3 PWR RUN ERR ALM SW1 ON SW2 EJ1-TC2 BCDE COM1 COM2 COM3 PWR RUN ERR ALM SW1 ON SW2 EJ1-TC2 DEF COM1 COM2 COM3 PWR RUN ERR ALM SW1 ON SW2 EJ1-TC2 DEF EJ1 G3ZA Multi-channel Power Controller EJ1N-TC2 @-QNHB EJ1N-TC4 Temperature controller Voltage output terminal (for driving SSR) SSR INPUT LOAD Load Heater Load power supply G3PF (SSRs with built-in CTs) Rated input voltage: 12 to 24 VDC 3 4 3 2 Converters, Digital Panel Meters, Flow Meters, Infrared Thermosensors, Displacement Sensors 240 VAC, 25 A or 35 A 480 VAC, 25 A or 35 A 240 VAC, 10 A, 20 A, 40 A, or 60 A 480 VAC, 20 A, 30 A, or 50 A 240 VAC, 5 A, 10 A, 20 A, 40 A, 75 A, or 90 A 480 VAC, 10 A, 20 A, 40 A, 75 A, or 90 A AGHTU OMR ON AGHTUR WNBVCDSIOLHGF AGHTUR WNBVCDSIOLHGF AGHTUR WNBVCDSIOLHGF AGHTUR WNBVC AGHTUR WNBVC AGHTU A A A A OMRON AGHTUR WNBVC AGHTUR AG AG AGHT G3PE (Single Phase) Ultra-compact and slim model combined with a heat radiator Rated input voltage: 12 to 24 VDC 240 VAC, 15 A, 25 A, 35 A, or 45 A 480 VAC, 15 A, 25 A, 35 A, or 45 A G3PE (Three Phase) Three-phase batch control combined with heat radiator Rated input voltage: 12 to 24 VDC 240 or 480 VAC, 15 A, 25 A, 35 A, or 45 A G3PA Ultra-compact and slim model combined with a heat radiator Rated input voltage: 240 V: 5 to 24 VDC 480 V: 12 to 24 VDC Analog quantities, such as temperature, flow rate, and concentration ES1B Infrared Thermosensor Thermocouple/Platinum Resistance Thermometer E52 G3NA Standard model with screw terminals Rated input voltage: 5 to 24 VDC G3NE Rated input voltage: 12 VDC 240 VAC, 5 A, 10 A, or 20 A 3 ∗The G3ZA is available with 4 or 8 control points. 4 G3PH For controlling high-power heaters Rated input voltage: 5 to 24 VDC 240 VAC, 75 A or 150 A 480 VAC, 75 A or 150 A Input device/sensor Can be directly connected. 1 Special Cable (Communications) ES2-HB-N Humidity Sensor ES2-THB-N Temperature/Humidity Sensor Number of SSRs That Can be Connected in Parallel Compact low-cost models with quick- connect terminals • Concept behind the Number of SSRs That Can Be Connected in Parallel (A): The maximum load current for the voltage output (to drive SSRs) for the Temperature Controller is 21 mA. (B): The input impedance for SSRs is 7 mA (G3NA). In this case, the number of SSRs that can be connected in parallel is (A) ÷ (B), therefore 3. The maximum load current in the connection example is 21 mA. EJ1N-TC2 @-CNB Two-channel SSR outputs can be connected to models with TC2 @-QNHB. The number of SSRs that can be connected for each channel is listed on the right. Four-channel SSR outputs can be connected to models with TC4. The number of SSRs that can be connected for each channel is listed on the right. · Two current output channels can be connected to the TC2 @-CNB. Four 480-VAC models (10 A/20 A/40A) One 240-VAC model (75 A/95 A) · Up to eight G3ZA or G3PW can be connected to each Basic Unit. Can be mounted side by side * ADJ SET EV B(+) A(-) RS-485 REMOTE SET DUTY SET EVENT RESET ALARM1(NPN) ALARM2(NPN) G3PW ENT RST LN 45 12 3 100-240VAC 1-5V +- +- 4-20mA %(IN) %(DUTY) %(OUT) %(PHASE) A COMM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ADJ SET EV B(+) A(-) RS-485 REMOTE SET DUTY SET EVENT RESET ALARM1(NPN) ALARM2(NPN) G3PW ENT RST LN 45 12 3 100-240VAC 1-5V +- +- 4-20mA %(IN) %(DUTY) %(OUT) %(PHASE) A COMM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ADJ SET EV B(+) A(-) RS-485 REMOTE SET DUTY SET EVENT RESET ALARM1(NPN) ALARM2(NPN) G3PW ENT RST LN 45 12 3 100-240VAC 1-5V +- +- 4-20mA %(IN) %(DUTY) %(OUT) %(PHASE) A COMM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Special Cable (Communications) Single-phase Power Controller G3PW * Side-by-side mounting is possible only for 20 A or 45 A models. Built-in CT for heater burnout detection and SSR short-circuit detection. |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |