| Moteur de recherche de fiches techniques de composants électroniques |
|
E5CD-RX2D6M-000 Fiches technique(PDF) 41 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CD-RX2D6M-000 Fiches technique(HTML) 41 Page - Omron Electronics LLC |
|
41 / 56 page ![]() E5CD/E5ED 41 SS S S M M M M M M M M M M M M M M M M M M M M M M M M M M M M Move to Calibration Level M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M 25 0 init off a1lt off a2lt off a3lt off a4lt off prlt 3 a1on 0 a2on 0 a3on 0 a4on 0 a1of 0 a2of 0 a3of 0 a4of 0 mant hold mani 0.0 rt off hsu on pf shft pfd1 1 pfd2 0 pfd3 0 pfd4 0 pfd5 0 spd1 4 spd2 0 pvst off svst off d.ref 0.25 cmov 0 hsl off hsh 0.1 lba 0 lbal 8.0 lbab 3.0 out1 o out2 none sub1 alm1 sub2 alm2 sub3 alm3 sub4 alm4 alma 49 t-u m alsp sp-m M M M pvrp 20 hctm 0 ompw 1.0 mspu off spru m rest a sb1n n-o sb2n n-o sb3n n-o sb4n n-o hbu on hbl off hbh 0.1 alfa 0.65 tidu 1 at-g 0.8 at-h 0.8 lcma 20.0 mav off M M M M ret off brgt 3 alt4 2 alh4 0.2 M alh3 0.2 ev-1 msp0 ev-2 stop sqr off Operation After Power ON M p-on cont amov 0 M M M M M cjc on manl off M M Llcmt 0.2 M M alt1 2 alh1 0.2 M alt2 2 alh2 0.2 M M alt3 2 M M M cp 20 c-cp 20 orev or-r M M M Bar Display Data mv bar Bar Display Scaling Upper Limit 100.0 barh Bar Display Scaling Lower Limit 0.0 barl Display Refresh Period PV/SP No. 1 Display Selection PV/SP No. 2 Display Selection Integral/Derivative Time Unit Integrated Alarm Assignment Moving Average Count Manual Output Method Manual MV Initial Value Heating/Cooling Tuning Method Minimum Output ON/OFF Band Display Brightness RT Monitor/Setting Item Level Monitor/Setting Item Display 1 Note: The monitor/setting items to be displayed is set in the Monitor/Setting Item 1 to 5 parameters (advanced function setting level). Monitor/Setting Item Display 2 Monitor/Setting Item Display 3 Monitor/Setting Item Display 4 Monitor/Setting Item Display 5 Press the O Key for at least 1 s. Advanced Function Setting Level Alarm 2 Type Alarm 3 Type Alarm 2 Hysteresis Alarm 3 Hysteresis Event Input Assignment 1 Event Input Assignment 2 Extraction of Square Root Enable Move by setting password ( −169). Parameter Initialization Number of Multi-SP Points SP Ramp Time Unit Standby Sequence Reset Auxiliary Output 1 Open in Alarm Auxiliary Output 2 Open in Alarm Auxiliary Output 3 Open in Alarm HB ON/OFF Heater Burnout Latch Heater Burnout Hysteresis AT Calculated Gain α AT Hysteresis Limit Cycle MV Amplitude Automatic Display Return Time Alarm 1 Latch Alarm 2 Latch Alarm 3 Latch Move to Protect Level Time Cold Junction Compensation Method Alarm 1 ON Delay Alarm 2 ON Delay Alarm 3 ON Delay Alarm 1 OFF Delay Alarm 2 OFF Delay Alarm 3 OFF Delay HS Alarm Use HS Alarm Latch HS Alarm Hysteresis LBA Detection Time LBA Level LBA Band Control Output 1 Assignment Control Output 2 Assignment Auxiliary Output 4 Assignment Soak Time Unit Alarm SP Selection Manual MV Limit Enable PV Rate of Change Calculation Period PF Setting Monitor/Setting Item 1 Monitor/Setting Item 2 Monitor/Setting Item 3 Monitor/Setting Item 4 Monitor/Setting Item 5 PV Status Display Function SV Status Display Function Auxiliary Output 4 Open in Alarm Alarm 4 Latch Alarm 4 ON Delay Alarm 4 OFF Delay Auxiliary Output 1 Assignment Auxiliary Output 2 Assignment Auxiliary Output 3 Assignment Alarm 4 Type Alarm 4 Hysteresis LCT Cooling Output Minimum ON Time Move to Advanced Function Setting LevelDisplayed when initial setting/communica- tions protect is set to 0. Control Period (Heating) Control Period (Cooling) Direct/Reverse Operation Alarm 1 Type Alarm 1 Hysteresis tr-t off tr-h 100.0 tr-l 0.0 o1st 4-20 trst 4-20 M M M M M Control output 1 Signal Transfer Output Signal Transfer Output Type Transfer Output Upper Limit Transfer Output Upper Limit M ev-6 none ev-5 none ev-4 none ev-3 none Event Input Assignment 3 to 6 50.0 a-dv 2.0 fasp 200 fahp 1.70 w-ic 0.90 w-dc ‘’0 pwtm 25 abtm 0 ra2m 0 ra1m 0 rac Adaptive Control Operation Possible Deviation 15.0 a-sd System Fluctuation Reference Deviation Automatic Filter Adjustment Seal Period Automatic Filter Adjustment Hunting Monitor Period Water-cooling Proportional Band Increase Constant Water-cooling Proportional Band Decrease Constant Power ON Time Monitor Ambient Temperature Monitor Control Output 1 ON/OFF Count Monitor Control Output 2 ON/OFF Count Monitor ON/OFF Counter Reset Parameter Mask Setting off pmst |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |