| Moteur de recherche de fiches techniques de composants électroniques |
|
9747 Fiches technique(PDF) 1 Page - Time Electronics Ltd. |
|
|
|||||||||||||||||||||||||||||
9747 Fiches technique(HTML) 1 Page - Time Electronics Ltd. |
|
1 / 2 page ![]() Easy Recalibration Recalibration is from the front panel or over the GPIB bus and takes less than 20 minutes. The Calibration constants are held in non-volatile memory so that no trimmer settings are required. A 'cal key' provides calibration security. EasyCal Calibration Software A fully automatic calibration station can be configured using Time Electronics PC based EasyCal software package. The user’s Instrument/Equipment data base is set up along with a calibration Procedure data base. Contained in the procedures are sets of pre-defined calibration tests for each type of instrument. When an instrument is ready for re-calibration the system automatically recalls the information and the PC automatically steps through the tests.. It sets up the calibrator over the GPIB bus and prompts the user to select the required range on the unit under test. On completion of the tests the results (which are calculated using the spec figures held in the Procedure) are written away to a Results database on the PC’s hard disk. Calibration certificates to ISO 9000 or Namas standard can be printed out on demand. EasyCal software is an optional extra and comes ready to run on a PC (Pentium + Windows 95 or better) . A GPIB interface card and cable are also required in the PC – available from Time Electronics or elsewhere. Inventory Management An optional add-on for EasyCal is Inventory Management. This allows the user to maintain his instrument/equipment database and keep track of where all the items are, additionally printed reminders can be sent out when re- calibrations are due. It is possible to keep records for a variety of equipment on the database – not only that which is calibrated by the system. 5022 Programmable Multi-Function Calibrator Time Electronics Limited, Botany Industrial Estate, Tonbridge, Kent, TN9 1RH. UK Telephone: 01732 355993 Fax: 01732 770312 E-Mail: mail@TimeElectronics.co.uk Web Site: www.TimeElectronics.co.uk 0 - 1 kV AC/DC Voltage 0-10A AC/DC Current 10Ω – 10MΩ Resistance GPIB interface Autocal facility EasyCal Calibration Software compatible The 5022 is a multi-function calibrator, with AC/DC voltage and current ranges plus resistance. It is suitable for calibration of digital and analogue multi-meters and a variety of general purpose measuring instruments. General Purpose Interface Bus (GPIB) The interface allows operation remotely from a PC or GPIB controller. Simple high level programming commands provide easy setting of range and value. Error condition readback is also provided. Offset and Deviation Offset is used to back off initial zero values on the unit under test and Deviation allows the output to be changed incrementally by up to +/-10%. The display then reads directly in % error which simplifies the calibration process. Error Detection and Self Test The internal software constantly monitors the output and displays and transmits (over the GPIB), error messages on detection of a fault or overload condition. A built in self-test program can also be run to check that key internal functions are operating correctly and help with fault diagnosis. Six Wave Forms from 15 Hz to 20 kHz in 5 Hz Steps In addition to DC and AC Sine output, square, trapezoidal, triangular, ramp up and down waveforms are available. This enables checking the true 'RMS' performance of multi-meters, linearity of chart recorders, and amplitude checks on oscilloscopes. Additionally, a slow sweep function allows analogue meters to be checked for sticking of the pointer. Safe High Voltage Operation Emphasis has been placed on safety. Output voltages greater than 50 volts can only be selected after pressing a safety interlock key. On selection of an output greater than 40V, a programmed 3 second delay, audio bleep and flashing led, warns the user. |
Numéro de pièce similaire - 9747 |
|
Description similaire - 9747 |
|
|
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |