54 / 60 page ![]() Bosch Sensortec | BME280 Data sheet 54 | 60 Modifications reserved | Data subject to change without notice Document number: BST-BME280-DS001-23 Revision_1.23_012022 10.2 Function return codes A list of the possible function return codes can be found below. 0 Sensor OK 10 Communication error or wrong device found 20 Trimming data out of bound 30 Temperature bond wire failure or MEMS defect 31 Pressure bond wire failure or MEMS defect 40 Implausible temperature (default limits: 0…40°C) 41 Implausible pressure (default limits: 900…1100 hPa) 42 Implausible humidity (default limits: 20...80 %rH) Error testing is done in ascending error code sequence. This means that if e.g. a trimming data error is detected (code 20), the temperature plausibility (code 40) is not checked anymore. Instead, error code 20 is returned and no others tests are performed. |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|