| Moteur de recherche de fiches techniques de composants électroniques |
|
M24M01-R Fiches technique(PDF) 21 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M24M01-R Fiches technique(HTML) 21 Page - STMicroelectronics |
|
21 / 47 page ![]() DocID12943 Rev 14 21/47 M24M01-R M24M01-DF Instructions 46 5.4 Read the lock status (M24M01-D only) The locked/unlocked status of the Identification page can be checked by transmitting a specific truncated command [Identification Page Write instruction + one data byte] to the device. The device returns an acknowledge bit if the Identification page is unlocked, otherwise a NoAck bit if the Identification page is locked. Right after this, it is recommended to transmit to the device a Start condition followed by a Stop condition, so that: • Start: the truncated command is not executed because the Start condition resets the device internal logic, • Stop: the device is then set back into Standby mode by the Stop condition. |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|