13 / 28 page ![]() Data Sheet 13 1.10 2018-09-13 TLE4929C Crankshaft Sensor Fully Programmable Crankshaft Sensor Figure 5 Operating Phases - Power-on to Running Phase t t HI uncalibrated mode calibrated mode Initial calib. time max min B 1 B2 B3 d d d VQ Bx,diff t t HI uncalibrated mode calibrated mode detected valid extremum used for switching threshold calculation first switching threshold correction (offset update) Initial calib. time 2 * ΔBlimit max min d d d 45 µs 45 µs 45 µs 45 µs 45 µs 45 µs LO detected valid extremum , used for switching threshold calculation first switching threshold correction (offset update) Bx,diff LO VQ 2 * ΔBlimit no pulse because of wrong slope of magnetic edge B 1 B2 B3 d = (max – min – adaptive _hysteresis ) / 2 d = (B3 –B1) / 2 d = (max – min – adaptive _hysteresis ) / 2 d = (B3 –B1) / 2 |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|