8 / 13 page ![]() Electrical specifications L9914 8/13 DS4742 Rev 7 Figure 4. Setpoint voltage vs. L terminal signal 2.5 Diagnostic Tj -35 °C to +150 °C unless otherwise specified. 2.5.1 Fault The following table lists the conditions that cause the fault driver to function (L terminal now switching between 0 V and VLSAT). To prevent L flicker, specific faults are required to be present for TDELAY seconds before the fault driver is activated. This delay is indicated in the following table. Table 7. Diagnostic Symbol Parameter Test conditions Min. Typ. Max. Unit VOV Overvoltage(1) - 16.5 - 22 V TDELAY Fault indication delay time - 0.935 1.1 1.265 s 1. When the VGO voltage overcomes this value the MFDC is cancelled. Table 8. Fault Conditions Delay 1. Key-on (RVC PWM signal acknowledgement) No 2. Phase voltage < VP2 and VGO < setpoint Yes |
|
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|