| Moteur de recherche de fiches techniques de composants électroniques |
|
R7ML Fiches technique(PDF) 17 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R7ML Fiches technique(HTML) 17 Page - M-System Co.,Ltd. |
|
17 / 40 page ![]() MODEL: R7ML http://www.m-system.co.jp/ R7ML SPECIFICATIONS ES-7805 Rev.11 Page 17/40 CIRCUIT DIAGRAM Note: In order to improve EMC performance, bond the FG terminal to ground. Caution: FG terminal is NOT a protective conductor terminal. Input Circuit Control Circuit ■ Input Circuit 1 7 6 0V 24VDC 3 FG * * *MECHATROLINK connectors are internally connected. The network cable can be connected to either one. Comm. Circuit 16 17 18 XB 15 X9 XF 10 XD 14 X7 13 X5 12 X3 11 X1 9 XE 8 XC 7 XA 6 X8 5 X6 4 X4 3 X2 2 X0 COM 1 COM 2 X0 18 XF Control Circuit ■ Input Connection Examples 1 2 X0 COM – + 18 XF PNP Connection 1 2 X0 COM – + 18 XF NPN Connection |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|