23 / 35 page ![]() 23/35 M45PE40 POWER-UP AND POWER-DOWN At Power-up and Power-down, the device must not be selected (that is Chip Select (S) must follow the voltage applied on VCC) until VCC reaches the correct value: –VCC(min) at Power-up, and then for a further delay of tVSL –VSS at Power-down Usually a simple pull-up resistor on Chip Select (S) can be used to ensure safe and proper Power-up and Power-down. To avoid data corruption and inadvertent write op- erations during power up, a Power On Reset (POR) circuit is included. The logic inside the de- vice is held reset while VCC is less than the Power On Reset (POR) threshold voltage, VWI – all oper- ations are disabled, and the device does not re- spond to any instruction. Moreover, the device ignores all Write Enable (WREN), Page Write (PW), Page Program (PP), Page Erase (PE) and Sector Erase (SE) instruc- tions until a time delay of tPUW has elapsed after the moment that VCC rises above the VWI thresh- old. However, the correct operation of the device is not guaranteed if, by this time, VCC is still below VCC(min). No Write, Program or Erase instructions should be sent until the later of: –tPUW after VCC passed the VWI threshold –tVSL after VCC passed the VCC(min) level These values are specified in Table 6.. If the delay, tVSL, has elapsed, after VCC has risen above VCC(min), the device can be selected for READ instructions even if the tPUW delay is not yet fully elapsed. As an extra protection, the Reset (Reset) signal can be driven Low for the whole duration of the Power-up and Power-down phases. At Power-up, the device is in the following state: – The device is in the Standby Power mode (not the Deep Power-down mode). – The Write Enable Latch (WEL) bit is reset. Normal precautions must be taken for supply rail decoupling, to stabilize the VCC supply. Each de- vice in a system should have the VCC rail decou- pled by a suitable capacitor close to the package pins. (Generally, this capacitor is of the order of 0.1µF). At Power-down, when VCC drops from the operat- ing voltage, to below the Power On Reset (POR) threshold voltage, VWI, all operations are disabled and the device does not respond to any instruc- tion. (The designer needs to be aware that if a Power-down occurs while a Write, Program or Erase cycle is in progress, some data corruption can result.) Figure 19. Power-up Timing VCC AI04009C VCC(min) VWI Reset State of the Device Chip Selection Not Allowed Program, Erase and Write Commands are Rejected by the Device tVSL tPUW time Read Access allowed Device fully accessible VCC(max) |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |