| Moteur de recherche de fiches techniques de composants électroniques |
|
ST7FDALIF2M6 Fiches technique(PDF) 103 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST7FDALIF2M6 Fiches technique(HTML) 103 Page - STMicroelectronics |
|
103 / 141 page ![]() ST7DALI 103/141 13.3.2 Operating Conditions with Low Voltage Detector (LVD) TA = -40 to 85°C, unless otherwise specified Note: 1. Not tested in production. 2. Not tested in production. The VDD rise time rate condition is needed to insure a correct device power-on and LVD reset. When the VDD slope is outside these values, the LVD may not ensure a proper reset of the MCU. 13.3.3 Auxiliary Voltage Detector (AVD) Thresholds TA = -40 to 85°C, unless otherwise specified Note: 1. Not tested in production. 13.3.4 Internal RC Oscillator and PLL The ST7 internal clock can be supplied by an internal RC oscillator and PLL (selectable by option byte). Symbol Parameter Conditions Min Typ Max Unit VIT+(LVD) Reset release threshold (VDD rise) High Threshold Med. Threshold Low Threshold 4.001) 3.40 1) 2.65 1) 4.25 3.60 2.90 4.50 3.80 3.15 V VIT-(LVD) Reset generation threshold (VDD fall) High Threshold Med. Threshold Low Threshold 3.80 3.20 2.40 4.05 3.40 2.70 4.30 1) 3.65 1) 2.901) Vhys LVD voltage threshold hysteresis VIT+(LVD)-VIT-(LVD) 200 mV VtPOR VDD rise time rate 2) 20 20000 µs/V tg(VDD) Filtered glitch delay on VDD Not detected by the LVD 150 ns IDD(LVD) LVD/AVD current consumption 220 µA Symbol Parameter Conditions Min Typ Max Unit VIT+(AVD) 1=>0 AVDF flag toggle threshold (VDD rise) High Threshold Med. Threshold Low Threshold 4.401) 3.901) 3.201) 4.70 4.10 3.40 5.00 4.30 3.60 V VIT-(AVD) 0=>1 AVDF flag toggle threshold (VDD fall) High Threshold Med. Threshold Low Threshold 4.30 3.70 2.90 4.60 3.90 3.20 4.901) 4.101) 3.401) Vhys AVD voltage threshold hysteresis VIT+(AVD)-VIT-(AVD) 150 mV ∆V IT- Voltage drop between AVD flag set and LVD reset activation VDD fall 0.45 V Symbol Parameter Conditions Min Typ Max Unit VDD(RC) Internal RC Oscillator operating voltage 2.4 5.5 V VDD(x4PLL) x4 PLL operating voltage 2.4 3.3 VDD(x8PLL) x8 PLL operating voltage 3.3 5.5 tSTARTUP PLL Startup time 60 PLL input clock (fPLL) cycles |
|
Lien URL |
| ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Lien vers la fiche technique | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |