2 / 5 page

HRF-ROC093XC
Advance Information
Web Site:
www.mysoiservices.com
Honeywell
Email:
mysoiservices@honeywell.com
Solid State Electronics Center
12001 State Highway 55
2003 09325XC
Published June 2003
Page 2
Plymouth, Minnesota 55441-4799
1-800-323-8295
RF Electrical Specifications @ + 25oC
Parameter
Test Condition
Frequency
Minimum
Typical
Maximum
Units
Rx Sensitivity
860– 928 MHz
-95
dBm
1db Compression
Vdd = 2.5V
860– 928 MHz
+5
dBm
Tx Output Power
Vdd = 2.5V
860– 928 MHz
+3
dBm
Tx Power Control
18
dB
Data Rate, Tx / Rx
Continuous Data
128
Kbps
Channel Rejection
Adjacent Channels
Fc + 1MHz
50
dB
Max Detection BW
IQ Baseband FilterPassband
250
KHz
Control/Data I/O
Serial Peripheral Interface (SPI). Direct
Connection To Microcontroller/Microprocessor
10
MHz
DC Electrical Specifications @ + 25oC
Parameter
Minimum
Typical
Maximum
Units
VDD Power Supply Voltage
2.4
2.5
2.6
V
Power Supply Current During Tx, Output Power
Dependant (915 MHz)
16
26
mA
Power Supply Current (IDD) During Rx (915MHz)
35
mA
Sleep Mode Current Consumption
<1
uA
CMOS Logic Level (0)
0
0.7
V
CMOS Logic Level (1)
1.7
VDD
V
Absolute Maximum Ratings1
Parameter
Absolute Maximum
Units
Maximum Input Power
VDD
ESD Voltage (Human Body Model)
Operating Temperature
Storage Temperature
-
+ 2.8
200
- 40 to + 85
- 40 to + 150
-
V
V
Degrees C
Degrees C
(Note 1) Operation Of The HRF-ROC093XC Beyond Any Of These Parameters May Cause Permanent Damage.
ESD Protection: The HRF-ROC093XC Contains reduced ESD Protection Circuitry for sensitive RF I/O. Precautions Should Be
Taken During Handling/Assembly Until Protected By External Circuitry or Housings