Moteur de recherche de fiches techniques de composants électroniques
  French  ▼
ALLDATASHEET.FR

X  

RUM Datasheet with Chat AI
  • AIauthorized

    Hello, Please ask a question about RUM Datasheet

  • # Example questions: ➢ What are the key differences between the ru and rum series in terms of packaging and intended applications?
    ➢ What isolation voltages are specified for input/output and output/output for both the standard and 'h' suffix versions of the ru/rum converters?
    ➢ What is the minimum load requirement for the ru/rum converters to maintain specifications, and what does the datasheet state about operation with loads below this minimum?

  • Part No.RUM
    ManufacturerRECOM
    Size97 Kbytes
    Pages2 pages
    DescriptionTwin Independent Outputs
    Datasheet Summary with AI

    1. Product Overview:

    ️· RU/RUM Series: These are isolated DC/DC converters with two independent outputs.
    ️· Key Features:
    - Isolated outputs (1kVDC input/output, output/output). "/H" versions offer 2kVDC isolation.
    - Compact size (especially the RUM series).
    - Wide input voltage range.
    - Suitable for applications requiring multiple isolated channels.
    ️· Typical Applications: Multiple channel circuits where inter-channel isolation is needed.

    2. Key Specifications:

    ️· Input Voltage: Varies by model (see selection guide).
    ️· Output Voltage: 5V and 3.3V models are shown in the example selection guide.
    ️· Output Current: 100mA per output.
    ️· Efficiency: Typically around 70-78%
    ️· Isolation Voltage: 1kVDC or 2kVDC (with the "/H" suffix)
    ️· Operating Temperature: -40°C to +85°C (with derating)

    3. Models & Selection Guide:

    ️· RU Series: Standard size.
    ️· RUM Series: Miniature size.
    ️· Suffixes:
    - /H: Indicates 2kVDC isolation.
    - /P: Indicates continuous short circuit protection.
    ️· The datasheet provides a selection guide showing several RU and RUM models with their specifications.

    4. Pinout and Package Details:

    ️· The datasheet includes detailed pinout diagrams for both the SIP7 (RU series) and SIP6 (RUM series) packages.
    ️· It also provides recommended footprint details for PCB layout.

    5. Important Notes and Disclaimers:

    ️· The datasheet emphasizes that the information is indicative and based on practical experience.
    ️· It includes a disclaimer regarding the use of RECOM products in safety-critical applications.
    ️· Information about MTBF (Mean Time Between Failures) is also provided.



    In essence, this document provides all the technical information needed to select, implement, and use RECOM's RU/RUM series DC/DC converters.

    1. Product Overview:

    ️· RU/RUM Series: These are isolated DC/DC converters with two independent outputs.
    ️· Key Features:
    - Isolated outputs (1kVDC input/output, output/output). "/H" versions offer 2kVDC isolation.
    - Compact size (especially the RUM series).
    - Wide input voltage range.
    - Suitable for applications requiring multiple isolated channels.
    ️· Typical Applications: Multiple channel circuits where inter-channel isolation is needed.

    2. Key Specifications:

    ️· Input Voltage: Varies by model (see selection guide).
    ️· Output Voltage: 5V and 3.3V models are shown in the example selection guide.
    ️· Output Current: 100mA per output.
    ️· Efficiency: Typically around 70-78%
    ️· Isolation Voltage: 1kVDC or 2kVDC (with the "/H" suffix)
    ️· Operating Temperature: -40°C to +85°C (with derating)

    3. Models & Selection Guide:

    ️· RU Series: Standard size.
    ️· RUM Series: Miniature size.
    ️· Suffixes:
    - /H: Indicates 2kVDC isolation.
    - /P: Indicates continuous short circuit protection.
    ️· The datasheet provides a selection guide showing several RU and RUM models with their specifications.

    4. Pinout and Package Details:

    ️· The datasheet includes detailed pinout diagrams for both the SIP7 (RU series) and SIP6 (RUM series) packages.
    ️· It also provides recommended footprint details for PCB layout.

    5. Important Notes and Disclaimers:

    ️· The datasheet emphasizes that the information is indicative and based on practical experience.
    ️· It includes a disclaimer regarding the use of RECOM products in safety-critical applications.
    ️· Information about MTBF (Mean Time Between Failures) is also provided.



    In essence, this document provides all the technical information needed to select, implement, and use RECOM's RU/RUM series DC/DC converters.

    Part No.RUM
    ManufacturerRECOM
    Size97 Kbytes
    Pages2 pages
    DescriptionTwin Independent Outputs
    ALLDATASHEET vous a-t-il été utile ?  [ DONATE ] 

    À propos de Alldatasheet   |   Publicité   |   Contactez-nous   |   Politique de confidentialité   |   Lien vers la fiche technique    |   Echange de liens   |   Fabricants
    All Rights Reserved©Alldatasheet.com


    Mirror Sites
    English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp