M2VF2-5WA-R2
AI

The **M2VF2-5WA-R2** is a high-performance **Industrial Signal Conditioner** (transducer) manufactured by **M-System**. It is specifically designed to convert alternating current (AC) input from a potential transformer into two isolated DC output signals.
---
## 1. Core Technical Specifications
| Feature | Specification |
| :--- | :--- |
| **Component Type** | AC Voltage Transmitter (V-Network) |
| **Input Signal** | AC Voltage (e.g., 0–110V, 0–220V AC) |
| **Output 1** | 4–20 mA DC |
| **Output 2** | 1–5 V DC |
| **Power Input** | 100–240V AC (indicated by "-R2" or "-M2" variants) |
| **Response Time** | ≤ 0.5 seconds (0 to 90%) |
| **Accuracy** | ±0.3% of span |
| **Isolation** | 3-way isolation (Input to Output to Power) |
---
## 2. Key Electronic Components & Internal Functions
The device functions through several electronic stages to ensure safety and precision:
### A. Input Transformation Stage
Since the input is high-voltage AC, the device contains a precision step-down transformer or a high-impedance voltage divider. This stage steps the voltage down to a millivolt level that the internal semiconductors can process safely.
### B. Rectification & Filtering
The AC signal is converted to DC using a **Full-Wave Rectifier** circuit. It then passes through a smoothing filter (low-pass filter) to remove ripples, ensuring the output represents the "True RMS" or "Mean Average" value of the input.
### C. Galvanic Isolation (The "3-Way" System)
To protect sensitive PLCs or SCADA systems from high-voltage surges, the M2VF2 uses:
* **Optical Isolators (Optocouplers):** For signal transmission between circuits.
* **Internal DC-DC Converter:** To provide isolated power to the input and output stages independently.
### D. Dual Output Driver
The "-5WA" designation indicates dual outputs. The internal circuitry splits the processed signal into two independent buffer amplifiers:
1. **Current Loop Driver:** Provides a constant 4-20mA signal, capable of driving long-distance wires.
2. **Voltage Driver:** Provides a 1-5V signal for local monitoring or PLC input.
---
## 3. Physical & Installation Features
* **Mounting:** Standard DIN-rail mounting.
* **Wiring:** M3.5 screw terminals.
* **Status Indication:** Typically features a power LED on the front panel to indicate the internal power supply is active.
* **Zero/Span Adjustments:** Accessible potentiometers on the front to calibrate the signal if the sensors drift over time.
---
- ⤷
What are the specific wiring diagrams for the M2VF2-5WA-R2?
- ⤷ Can this unit handle True RMS measurement for distorted waveforms?
- ⤷ What is the difference between the R2 and M2 power supply suffixes?