IXI848 Datasheet with Chat AI
  • AIauthorized

    Hello, Please ask a question about IXI848 Datasheet

  • # Example questions: ➢ What resistance value is recommended for a full-scale current of 0.01a?
    ➢ The datasheet mentions output impedance and the impact of external load (rload). what are the output impedances for gain settings of 10 and 50, respectively?
    ➢ What are the two selectable gain options for the ixi848?

  • Part No.IXI848
    ManufacturerIXYS
    Size235 Kbytes
    Pages5 pages
    DescriptionHigh-Side Current Monitor
    Datasheet Summary with AI

    Okay, I've analyzed the provided text related to the IXI848 current sense amplifier. Here's a summary of the key information, organized for clarity:

    1. Device Overview:

    ️· What it is: The IXI848 is a precision current sense amplifier.
    ️· Function: It measures current by sensing the voltage drop across a shunt resistor (RSENSE).
    ️· Input Voltage Range: 2.7V to 40V

    2. Key Features & Specifications:

    ️· Gain Options: Selectable gain of 10 or 50.
    ️· Output Impedance: 33kΩ for gain of 10, 165kΩ for gain of 50. This influences accuracy when driving loads.
    ️· Temperature Coefficient of Resistors: 700 ppm/°C (important for temperature-dependent accuracy).
    ️· Output Configuration: Current source driving a resistor, which allows it to act as a voltage source.

    3. RSENSE Selection & Current Measurement:

    ️· The choice of RSENSE is crucial for accurate current measurement. It should be selected so that the voltage drop across it (and therefore the output of the amplifier) is within a usable range.
    ️· A table is provided showing recommended RSENSE values for different full-scale current measurements (IL). For example, for IL=0.15A, RSENSE would be 1.0 Ohm.

    4. Output Loading Considerations:

    ️· The amplifier's output impedance will influence measurement accuracy if the output is loaded. A high-impedance load is preferred to minimize error.
    ️· Formulas are provided to calculate the percent error introduced by output loading.

    5. Additional Information (from the other pages):

    *The document seems to be missing significant portions, but some tables and data are present. I don't have enough information to create a comprehensive document summary.



    In essence, the IXI848 is a versatile current sense amplifier designed for precision measurements, but careful consideration of RSENSE selection and output loading is necessary for optimal performance.

    1. Device Overview:

    ️· What it is: The IXI848 is a precision current sense amplifier.
    ️· Function: It measures current by sensing the voltage drop across a shunt resistor (RSENSE).
    ️· Input Voltage Range: 2.7V to 40V

    2. Key Features & Specifications:

    ️· Gain Options: Selectable gain of 10 or 50.
    ️· Output Impedance: 33kΩ for gain of 10, 165kΩ for gain of 50. This influences accuracy when driving loads.
    ️· Temperature Coefficient of Resistors: 700 ppm/°C (important for temperature-dependent accuracy).
    ️· Output Configuration: Current source driving a resistor, which allows it to act as a voltage source.

    3. RSENSE Selection & Current Measurement:

    ️· The choice of RSENSE is crucial for accurate current measurement. It should be selected so that the voltage drop across it (and therefore the output of the amplifier) is within a usable range.
    ️· A table is provided showing recommended RSENSE values for different full-scale current measurements (IL). For example, for IL=0.15A, RSENSE would be 1.0 Ohm.

    4. Output Loading Considerations:

    ️· The amplifier's output impedance will influence measurement accuracy if the output is loaded. A high-impedance load is preferred to minimize error.
    ️· Formulas are provided to calculate the percent error introduced by output loading.

    5. Additional Information (from the other pages):

    *The document seems to be missing significant portions, but some tables and data are present. I don't have enough information to create a comprehensive document summary.



    In essence, the IXI848 is a versatile current sense amplifier designed for precision measurements, but careful consideration of RSENSE selection and output loading is necessary for optimal performance.

    Part No.IXI848
    ManufacturerIXYS
    Size235 Kbytes
    Pages5 pages
    DescriptionHigh-Side Current Monitor
    ALLDATASHEET vous a-t-il été utile ?  [ DONATE ] 

    À propos de Alldatasheet   |   Publicité   |   Contactez-nous   |   Politique de confidentialité   |   Lien vers la fiche technique    |   Echange de liens   |   Fabricants
    All Rights Reserved©Alldatasheet.com


    Mirror Sites
    English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
    Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
    Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
    Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
    Family Site : ic2ic.com  |   icmetro.com